The pH sensor 7112 is a high-quality original replacement part for the HORIBA U-50 series of multiparameter measuring devices. It enables precise and reliable pH measurements in a wide range of water quality applications – from environmental monitoring to industrial process control.Quick replacement – can be mounted on the U-50 probe unit without toolsDurable & robust – designed for use in harsh environmental conditions Manufacturer article number: 3014057312
The Milwaukee MA840 is a polarographic replacement probe for the MW600 Dissolved Oxygen meter.The refillable polarographic probe has an oxygen-permeable polytetrafluroethylene (PTFE) membrane sensor for measuring dissolved oxygen (DO) levels in aqueous solutions.The probe uses a platinum cathode and a silver chloride anode which the MW600 meter polarizes so that oxygen passing through the membrane can be measured to produce stable, accurate readings.DESIGN FEATURESReinforced plastic body for durabilityBuilt in temperature sensor to achieve thermal equilibrium between the sensor and the sample for more accurate reading25,4cm long with a tip that tapers from 1-1/2" to 3/4" in diameter3m cable with a 7-pin DIN connector for attaching to the meter
The Milwaukee MA860 is a Galvanic replacement probe for the MW605 MAX Dissolved Oxygen meter.The refillable Galvanic probe has an oxygen-permeable polytetrafluroethylene (PTFE) membrane sensor for measuring dissolved oxygen (DO) levels in aqueous solutions and a built in temperature sensor.The probe uses a silver cathode and a zinc anode.The body is made of PP and ABS.DESIGN FEATURESReinforced plastic PP, ABS for durabilityBuilt in temperature sensor to achieve thermal equilibrium between the sensor and the sample for more accurate reading160 mm long with a tip that tapers from 1-1/2" to 3/4" in diameter3.0 m cable with a 7-pin DIN connector for attaching to the meter
The Milwaukee MA861 Dissolved Oxygen Membranes are compatible with the MA860 Galvanic Dissolved Oxygen Probe used on the MW605 MAX Dissolved Oxygen Meter.DESIGN FEATURESOxygen-permeable polytetrafluroethylene (PTFE) membrane sensorEasy to fill with MA9072S Oxygen Electrolyte SolutionIncludes membranes and 5x o-rings
The Milwaukee MA906BR/1 Reinforced pH/Redox/Temp replacement electrode for Milwaukee MW105 pH/Temp and MW106 pH/ORP/Temp meters.The MA906BR/1 has a rugged housing (epoxy) and comes with a 1m cable and BNC connector (meters sold separately).OPR probes for MW105 or MW106 are available separately.The probe connects quickly and firmly to a BNC connector. No slipping off is to be feared.
The MA911B/2 probe is lab grade, gel-filled pH probe for use with Milwaukee Monitors and Controllers.DESIGN FEATURESTop features include:DOUBLE JUNCTIONThe double junction junction design reduces the risk of clogging.SPHERICAL GLASS TIPThe sperical glass tip provide the largest possible surface area for faster results.RESIN BODYThe resin body is tough to withstand accidental knocks and also protects the glass sensing bulb.EXTENDED CABLEOffers a 2m cable for increased flexibility in measuring.USE AND CAREpH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.SENSING BULBThe glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.REFERENCE JUNCTIONThe reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH probe will no longer function. You can extend the life of your pH electrode in the following ways.STORAGEThe pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged. Storing in pH probe storage solution or pH calibration buffers will help address both these issues. Do not store in tap water and DI water. This will damage the sensitivity of the probe. The best way to store the probe is with the probe's cap filled with storage solution or calibiration buffer and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage. CLEANINGResidue from the sample can impact the sensitivity of the sensing bulb and block the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution.CALIBRATIONThe pH sensing bulbs become less sensitive over time so make sure that you are calibrating regularly to keep your PRO pH meter accurate. Also, calibrate after cleaning or a long period of storage.
The MA917B/1 probe makes pH testing easy and fast.Top features include:DOUBLE JUNCTIONThe double junction design reduces risk of clogging with the reference cell physically separated from the intermediate electrolyte.REFILLABLEThe MA917B/1 refillable with MA9011 3.5M KCl. This solution is sliver free. Sliver can cause silver precipitate to form at the junction resulting in clogging. Clogging causes erratic and slow readings. The ability to refill the electrolyte also extends the life of the electrode.GLASS BODYThe glass body is easily cleaned and resistant to chemicals.ROUND TIPThe round design of the tip provides the largest possible surface area for faster readings and is well suited to testing liquid samples.
DESIGN FEATURESThe MA924B/1 offers the following design features:PLATINUM SENSING RINGThe platinum ring design is the preferred for most ORP applications.GLASS BODYGlass body is ideal use in wine applications as it is easily cleaned and gives fast results.DOUBLE JUNCTION REFERENCEThe double junction means that virtually no silver from the reference cell is mixed with the sample and reduces the risks of clogging.REFILLABLEThe ability to refill the electrolyte solution extends the life of the probe. Use MA9011 3.5M KCl fill solution. With a refillable ORP electrode, best results are achieved if the fill cap is removed to create a higher flow rate. This results in a faster and more stable reading.
Accessories for the handy photometers MW10, MW11, MW13 and MW14 (art. no. 895547, 895548, 895549, 895550).These replacement glass cuvettes are made of high quality glass with perfect properties to ensure that light refraction is not distorted and readings are correct and accurate every time.The set contains 2x (10 ml) high quality glass cuvettes.
The Milwaukee MI0013 are replacement plastic stoppers for the MI0011 glass cuvettes.The replacement stoppers are designed to fit perfectly on the MI0011 glass cuvettes to prevent any leakage.The set contains 2 high-quality stoppers for MI0011 glass cuvettes.
Manufacturer article number: Mi56P
Manufacturer article number: Mi57P
Manufacturer article number: Mi58P
Manufacturer article number: Mi59P
Manufacturer article number: Mi60P
Manufacturer number: 50110172
Original spare part from HORIBA – guaranteed to fit the U-50 series perfectlyThe Horiba Reference Electrode Tip 7210 is a high-quality replacement part designed specifically for Horiba's U50 series of multiparameter measuring devices. It ensures a precise and stable reference voltage, which is essential for reliable measurement results in demanding environmental and water analyses. The electrode tip is easy to replace and helps to extend the service life of the entire system. Thanks to its robust design, it is ideal for use in harsh field conditions. With the 7210 reference electrode tip, your U50 measuring device will always be ready for use and perform at its best. Manufacturer article number: 3200043582
To ensure measurements remain reliable and accurate, it is important to regularly check the sensor and replace it with a spare sensor if necessary. The replacement sensor is specifically designed for the HORIBA LAQUAtwin Ca-11C for animal blood. This sensor is engineered to optimize user-friendliness and accuracy. With HORIBA replacement sensors, users can be confident that their devices consistently deliver optimal performance and precise results. Advantages of HORIBA Replacement Sensors: Easy Replacement: Sensors can be quickly replaced, allowing measurements to continue without delay. High Accuracy: Replacement sensors ensure that results are precise and reliable. Comprehensive Measurement Range: Various sensor types are available to measure a wide range of parameters. Durability: Sensors are designed for long service life, even under challenging conditions. Sensor Replacement Instructions: To ensure the longevity and accuracy of your HORIBA LAQUAtwin Pocket Tester, please follow these instructions when replacing a sensor: Removing the Sensor: Turn off the tester. Carefully detach the sensor from the device and lift the sensor tip. Completely separate the sensor from the tester so that the two components are no longer connected. Installing the Sensor: Ensure the tester is turned off. Check that the waterproof gasket is clean and intact. Attach the sensor to the tester by inserting hook “A” on the back of the device into hole “a” on the sensor tip. Make sure the waterproof gasket is not twisted. Important: After replacing the sensor, it is essential to follow the steps in the user manual of the respective tester to make the device ready for accurate measurements. These manuals are available with the products. Calibration and, if necessary, conditioning are usually required. How can I tell if my sensor shows signs of wear? Check the sensor condition as follows: Perform a 2-point calibration to assess the sensor’s condition. If an error occurs during calibration, this indicates that the sensor has deteriorated. In this case, replacing the sensor is recommended. Regular checks and timely replacement of sensors are essential to maintain the high standards and reliability of water quality measurements performed with HORIBA LAQUAtwin Pocket Testers. S051 Calcium replacement sensor for Ca-11C Manufacturer article number: 3200772945
Manufacturer number: 50010252
Manufacturer number: 50002072Gel filling with porous separator, maintenance-free, fixed cable 3m, pH 0 to 14, temperature 0 to 60°C
Manufacturer number: 32200153Gel filling with porous separator, maintenance-free, fixed cable 3m, pH 0 to 14, temperature 0 to 60°C
Manufacturer article number: 50014413
Manufacturer number: 50004002
Manufacturer number: 50002082