In our online shop we offer you a broad product portfolio of various pocket testers. You can select the right pocket tester for you according to various criteria: measurement parameters, application area, quality features or manufacturer.
With the uncomplicated to handle portable analyzers, the measurement of viscous liquids, solids and even powder samples is possible. Only a few drops of the standard solution or sample on the highly sensitive sensor are required to obtain fast and reliable test results. This procedure saves you time and, in addition to industrial use, also allows the handheld meters to be used in the home.
At the same time, the integrated analysis function, the large illuminated display and the replaceable batteries make the handheld analyzer from Horiba very user-friendly.
Our instruments are used, among others, in:
- Water or liquid analysis
- Conformity testing
- Food or environmental analysis
- Quality control
- Biotechnology
Choose your pocket tester from the different brands:
- Horiba
- Milwaukee
- XS Instruments
Filter products
With the pH buffer solution (pH 10.01), you can calibrate your electrodes easily and precisely. It is well-suited for various applications such as laboratory analysis or food monitoring. The Neomeris pH 10.01 buffer solution (± 0.02 pH at 25 °C) provides a stable, ready-to-use reference solution for calibrating your pH electrodes in the alkaline range. Before any pH measurement, your electrode should be calibrated with a buffer solution to avoid measurement deviations. Calibration solution for precise pH measurements The buffer solution provides a reliable reference value of pH 10.01 ± 0.02 at 25 °C and ensures accurate calibration of your pH electrodes for demanding measurement tasks. It pairs perfectly with other buffer solutions (e.g., pH 7.00 or pH 4.00) for multi-point calibration. The solution is colored yellow. Versatile applications Laboratory analysis Environmental and water analysis Food monitoring Research & education Industrial processes Frequently asked questions Where can I find the safety data sheet for the solution I want to use? The safety data sheet is included in printed form with the delivery of the goods. The safety data sheet can be viewed or downloaded at any time in the download area of the online shop. What bottle sizes are available? Generally, there are 60/70 ml, 250 ml, 500 ml and 1,000 ml bottles. There is one exception, for example, with brands such as Hanna, where bags are sold instead of bottles. How long do the solutions last? The shelf life is printed on the product label. Upon delivery, the shelf life is at least 7 months. Can the solutions still be used after the expiry date? No, because the function and quality can no longer be guaranteed after the best-before date has expired. How can I dispose of the solutions? Please refer to the safety data sheet for more detailed information on the disposal of the solutions. Disposal must be carried out in accordance with official regulations. What is the emergency number for acute poisoning? The emergency number for the North Poison Information Centre is +49 551-19240 and is available 24/7.
Neomeris pH buffer solution pH 9.21 (± 0.01 pH at 25 °C) is a ready-to-use reference solution for calibrating your pH electrodes in the alkaline range. Maximum stability for your pH measurement The buffer solution provides a defined pH value of 9.21 ± 0.01 at 25 °C and ensures stable results when calibrating your pH electrodes. Before each measurement, your electrode should be calibrated with a buffer solution to avoid measurement deviations. The blue-coloured solution makes it easy to quickly distinguish it from other buffer solutions. Tip: For precise multi-point calibration, this solution can be ideally combined with other Neomeris buffer solutions such as pH 4.01 and pH 10.00. Different areas of application Laboratory analysis Environmental and water analysis Food monitoring Research and teaching Industrial processes Frequently asked questions Where can I find the safety data sheet for the solution I want to use? The safety data sheet is included in printed form with the delivery of the goods. The safety data sheet can be viewed or downloaded at any time in the download area of the online shop. What bottle sizes are available? Generally, there are 60/70 ml, 250 ml, 500 ml and 1,000 ml bottles. There is one exception, for example, with brands such as Hanna, where bags are sold instead of bottles. How long do the solutions last? The shelf life is printed on the product label. Upon delivery, the shelf life is at least 7 months. Can the solutions still be used after the expiry date? No, because the function and quality can no longer be guaranteed after the best-before date has expired. How can I dispose of the solutions? Please refer to the safety data sheet for more detailed information on the disposal of the solutions. Disposal must be carried out in accordance with official regulations. What is the emergency number for acute poisoning? The emergency number for the North Poison Information Centre is +49 551-19240 and is available 24/7.
Manufacturer number: HI98303Scope of delivery:CR2032 battery (one piece)protective capinstruction manualQuality certificate1413 µS/cm calibration solution 20ml, four bags
Manufacturer number: HI98304Scope of delivery:CR2032 battery (one piece)protective capinstruction manualQuality certificate12.88 mS/cm calibration solution 20ml, four bags
Manufacturer number: HI98108Scope of delivery:CR2032 battery (one piece)protective capinstruction manualQuality certificateElectrode cleaning solution, one bagpH 4.01 calibration solution 20ml, one bagpH 7.01 calibration solution 20ml, two bags
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester. Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely. NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement. Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm). Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm. TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements. ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Important note regarding compatibility Please note: The replacement sensors, both old and new, are not compatible with one another. Similarly, the conditioning solutions for the old and new versions are not compatible with the respective device models. How can you tell if you have an older or a new device? If your Pocket Tester is marked ‘4-cell’, you have the latest version of this device. In this case, you will need the replacement sensors listed in the cross-selling section, as well as the standard and conditioning solutions. These have been specially optimised for the new Pocket Testers and are not suitable for the older models. Manufacturer Part No. 3999960112
Optimise your fluoride measurements with this high-quality standard solution – ideal for precise calibration of measuring instruments such as the HORIBA LAQUAtwin F-11. Key features: Concentrated standard solution: 1 ppm fluoride ions – ideal for calibration in the low measurement range.Practical pack: 6 vials of 14 ml each – perfect for frequent and economical use.Compatible with LAQUAtwin F-11: Often used together with 10 ppm and TISAB solutions for two-point calibration. Advantages & application: Maximum accuracy: Calibrate your fluoride measuring devices precisely with the 1 ppm solution – ideal as the first calibration point for a more reliable measurement result.Compact & efficient: Thanks to the 14 ml vials, you can calibrate precisely, avoid waste and save costs.Standard solutions from a single source: Easily supplement with 10 ppm standard and TISAB solutions for a comprehensive calibration series.Easy to use: Just a few drops are enough for calibration – particularly user-friendly for mobile measuring devices or small sample quantities. Areas of application: Environmental analysis & water qualityDrinking water monitoringFood & beverage industrySemiconductor and pharmaceutical industryLaboratories and research Manufacturer item number: 3200991628
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200991630
HORIBA Ion standard solutions, ionic strength controllers and ion-selective electrode filling solutions are indispensable for accurate and reproducible measurements with ion-selective electrodes (ISE). A large number of analyses in laboratories and in the field, such as testing water and wastewater quality, environmental monitoring and quality control in industrial processes, rely on these solutions. Ionic standard solutions are used to calibrate ion-selective electrodes and ensure precise measurement. Horiba's standard solutions have a known ion concentration. They are therefore essential for setting up the electrodes correctly before using them for test runs. Ionic strength regulators are specifically designed to adjust the ionic strength of the sample to enable accurate measurements. They are particularly important when the composition of the samples could affect the measurement or in samples with low ionic strength. The ionic strength can be adjusted to stabilize the ionic activity in the solution. This leads to more accurate measurement results. Ion-selective electrode filling solutionsIon-selective electrode filling solutions are specific solutions that are filled into ion-selective electrodes. They ensure the proper operation of the electrode and help to maintain the potential required to measure the specific ion. To ensure that measurements meet international standards and to ensure conformity with regulatory and compliance standards, these specialized solutions are essential. Many industries, from pharmaceutical to environmental, use these solutions to meet their quality and safety requirements. For users working in areas such as water analysis, environmental monitoring or regulatory testing environments, these solutions ensure the accuracy and reliability required for critical measurements. To provide reliable data for important environmental, health and safety decisions, they are a crucial part of analytical chemistry. Overall, HORIBA's solutions enable experts to make the best use of their instruments and achieve the precise results required for their applications. Manufacturer article number: 3200697168 (500-CL-SL)
HORIBA Ion standard solutions, ionic strength controllers and ion-selective electrode filling solutions are indispensable for accurate and reproducible measurements with ion-selective electrodes (ISE). A large number of analyses in laboratories and in the field, such as testing water and wastewater quality, environmental monitoring and quality control in industrial processes, rely on these solutions. Ionic standard solutions are used to calibrate ion-selective electrodes and ensure precise measurement. Horiba's standard solutions have a known ion concentration. They are therefore essential for setting up the electrodes correctly before using them for test runs. Ionic strength regulators are specifically designed to adjust the ionic strength of the sample to enable accurate measurements. They are particularly important when the composition of the samples could affect the measurement or in samples with low ionic strength. The ionic strength can be adjusted to stabilize the ionic activity in the solution. This leads to more accurate measurement results. Ion-selective electrode filling solutionsIon-selective electrode filling solutions are specific solutions that are filled into ion-selective electrodes. They ensure the proper operation of the electrode and help to maintain the potential required to measure the specific ion. To ensure that measurements meet international standards and to ensure conformity with regulatory and compliance standards, these specialized solutions are essential. Many industries, from pharmaceutical to environmental, use these solutions to meet their quality and safety requirements. For users working in areas such as water analysis, environmental monitoring or regulatory testing environments, these solutions ensure the accuracy and reliability required for critical measurements. To provide reliable data for important environmental, health and safety decisions, they are a crucial part of analytical chemistry. Overall, HORIBA's solutions enable experts to make the best use of their instruments and achieve the precise results required for their applications. Manufacturer article number: 3200697167 (500-CL-SH)
The HORIBA 12.9 mS/cm conductivity standard solution is a reliable calibration solution for high-quality LAQUAtwin EC conductivity meters. This standard solution is precisely preset to a conductivity of 12.9 mS/cm, ensuring fast and reliable calibration of your measuring instruments. Areas of application Ideal for regular calibration and quality control in laboratories, environmental analysis and industrial processes, especially in combination with HORIBA LAQUAtwin EC series instruments. Product advantages at a glance Precise and reproducible conductivity of 12.9 mS/cmSuitable for HORIBA LAQUAtwin EC measuring devicesEasy to use: ready to use, preconfiguredBottle size 14 ml: practical and handy Manufacturer item number: 3999960111
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3999960110
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200457728
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200053536
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200457720
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200457724
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200457727
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200053532
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200457719
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200457723
Explore HORIBA's premium profile solutions for pH, ORP and conductivity measurements, specifically designed for handheld and laboratory meters. Our solutions are designed to meet the needs of different users and ensure that your measurements are accurate. Here are a few of our products that provide a clear overview and easy selection: - pH standard solutions are available in different pH value classes: e.g. 4.01, 7.00, 10.01. These solutions are indispensable for the calibration of pH electrodes and have a high degree of accuracy. - Redox standard solutions (ORP): These solutions offer values from 200 mV to 650 mV, enabling precise adjustment of redox electrodes. Standard solutions for conductivity: These are used to calibrate conductivity sensors and are available in different conductivity ranges. - Internal filling solutions: These solutions are specially designed for pH and reference electrodes and ensure optimum functionality as well as a long service life for your electrodes. Users:- Our NIST-traceable hygienic bottle solutions are ideal for environmental laboratories using pH and ORP buffer solutions to monitor water quality in natural waters. They enable safe and accurate calibration without the risk of contamination. - Our buffer solutions provide a reliable basis for compliant results in the pharmaceutical industry, where accurate pH measurements are critical for drug formulation and quality control. - Our pH and redox solutions are of great importance to the food and beverage industry and play a crucial role in the quality of products, from wine production to milk processing. - Our solutions are used by research institutions and universities to conduct their scientific experiments and train the next generation of scientists. - Our conductivity standard solutions are used by water treatment plants to improve their purification and filtration processes. Manufacturer information: Because HORIBA is synonymous with quality and precision, you can trust our professional solutions to complement your measurement equipment and extend its life. HORIBA's innovative hygienic bottles differ significantly from conventional bottles as they allow contamination-free removal by simply squeezing. As the lower part of the bottle always remains fresh and untouched, it is particularly advantageous for applications where cleanliness and accuracy are crucial. Use HORIBA solutions to ensure the accuracy of your measurements and promote the functionality of your measuring devices. HORIBA high quality conductivity calibration solution to calibrate your electrodes The 250 ml, 500 ml and 1000 ml bottle is characterized by a special hygienic closure, which protects the conductivity calibration solution from contamination. To provide the required calibration solution, simply squeeze the bottle together and enough conductivity calibration solution is delivered to the upper part of the bottle to perform a calibration.
Calcium (Ca2+) ion-selective electrode for 300 seriesThe new electrode is suitable for the LAQUA WQ-300 series from Horiba and offers precise and reliable measurements for ions in aqueous solutions. It is characterised by its user-friendly handling and environmentally friendly design and can be used for a wide range of applications.Linearity in measurement range:The range where the calibration curve has linearity is called the measurement range. When lower concentration is measured where the linearity is not established, perform calibration at two points in the lower concentration range.Below graph shows the theoretical calibration curve of a calcium ion selective electrode.Influence of pH:The impact of the pH may cause a decrease in the slope of the ion selective electrode, or parallel shifting of the calibration curve. To prevent these effects, set the pH to an appropriate value in advance and keep it constant.Interfering ions:Ion selective electrodes have good selectivity with respect to the ions to be measured, but they may react to the other ions. When using the ion electrode method, it is important to know the effects of coexistent ions and take measures to avoid them. Interfering ions may form compounds with poor solubility or may form complex salts with the structure material of the ion selective membrane, these may to have a significant impact on the measured value.Conditioning:An electrode is conditioned by soaking it in a standard solution for 1 hour or longer. Use a standard solution whose concentration is 100 mg/L or more.In the following cases, perform conditioning of the electrode before calibration.• Before the first use.• Before use after storage for 2 weeks or longer.• If the electrode is less responsive.Calibration:Always calibrate with at least 2 calibration solutions which are 1 decade apart and bracket the expected measurement value.Use fresh calibration solutions and do not re-use them.• Below 10 ppm (mg/L)First solution between 1 and 10ppmSecond solution between 10 and 50 ppm• Between 10 and 100 ppm (mg/L)First solution between 10 and 100ppmSecond solution between 100 and 1000 ppm• Above 100 ppm (mg/L)First solution between 100 and 1000ppmFurther information can be found in the download area of the store. Manufacturer article number: 3200986786 (300-CA-C)
Potassium (K+) ion-selective electrode for 300 series The new electrode is suitable for the LAQUA WQ-300 series from Horiba and offers precise and reliable measurements for ions in aqueous solutions. It is characterised by its user-friendly handling and environmentally friendly design and can be used for a wide range of applications.Features:Measurement parameters: Potassium (K+) Solid-state electrodes that do not require refilling Double junction made of porous sintered polyethylene Integrated temperature sensor Environmentally friendly design made from bio-based plastic Supplied with calibration and ionic strength adjustment solutions Robust housing made of polycarbonate and PVC Low maintenance, simply rinse and seal Waterproof according to IP67Linearity in measurement range:The range where the calibration curve has linearity is called the measurement range. When lower concentration is measured where the linearity is not established, perform calibration at two points in the lower concentration range.Influence of pH:The impact of the pH may cause a decrease in the slope of the ion selective electrode, or parallel shifting of the calibration curve. To prevent these effects, set the pH to an appropriate value in advance and keep it constant.→Set the pH to an appropriate value in advance and keep it constant.If the pH of the sample solution exceeds 11, adjust the pH in the range of 5 to 11 by adding hydrochloric acid HCl.If the pH of the sample solution is less than 5, adjust the pH in the range of 5 to 11 by adding sodium hydroxide NaOH.Interfering ions:Ion selective electrodes have good selectivity with respect to the ions to be measured, but they may react to the other ions. When using the ion electrode method, it is important to know the effects of coexistent ions and take measures to avoid them. Interfering ions may form compounds with poor solubility or may form complex salts with the structure material of the ion selective membrane, these may to have a significant impact on the measured value. Conditioning:An electrode is conditioned by soaking it in a standard solution for 1 hour or longer. Use a standard solution whose concentration is 100 mg/L or more.In the following cases, perform conditioning of the electrode before calibration.• Before the first use.• Before use after storage for 2 weeks or longer.• If the electrode is less responsive.Calibration:Always calibrate with at least 2 calibration solutions which are 1 decade apart and bracket the expected measurement value.Use fresh calibration solutions and do not re-use them.• Below 10 ppm (mg/L)First solution between 1 and 10ppmSecond solution between 10 and 50 ppm• Between 10 and 100 ppm (mg/L)First solution between 10 and 100ppmSecond solution between 100 and 1000 ppm• Above 100 ppm (mg/L)First solution between 100 and 1000ppmSecond solution above 1000 ppmFurther information can be found in the data sheets in the download area of the store. Manufacturer article number: 3200986785 (300-K-C)
Sodium (Na+) ion-selective electrode for 300 seriesThe new electrode is suitable for the LAQUA WQ-300 series from Horiba and offers precise and reliable measurements for ions in aqueous solutions. It is characterized by its user-friendly handling and environmentally friendly design and is versatile in use. Features:Measurement parameters: Sodium (Na+)Solid-state electrodes that do not require refillingDouble junction made of porous sintered polyethyleneIntegrated temperature sensorEnvironmentally friendly design made from bio-based plasticDelivery includes calibration and ionic strength adjustment solutionsRobust housing made of polycarbonate and PVCLow maintenance, simply rinse and sealWaterproof according to IP67Linearity in measurement range:The range where the calibration curve has linearity is called the measurement range. When lower concentration is measured where the linearity is not established, perform calibration at two points in the lower concentration range.Influence of pH:The impact of the pH may cause a decrease in the slope of the ion selective electrode, or parallel shifting of the calibration curve. To prevent these effects, set the pH to an appropriate value in advance and keep it constant.→Set the pH to an appropriate value in advance and keep it constant.If the pH of the sample solution exceeds 10, adjust the pH in the range of 5 to 10 by adding hydrochloric acid HCl.If the pH of the sample solution is less than 5, adjust the pH in the range of 5 to 10 by adding sodium hydroxide NaOH.Interfering ions:Ion selective electrodes have good selectivity with respect to the ions to be measured, but they may react to the other ions. When using the ion electrode method, it is important to know the effects of coexistent ions and take measures to avoid them. Interfering ions may form compounds with poor solubility or may form complex salts with the structure material of the ion selective membrane, these may to have a significant impact on the measured value. Conditioning:An electrode is conditioned by soaking it in a standard solution for 1 hour or longer. Use a standard solution whose concentration is 100 mg/L or more.In the following cases, perform conditioning of the electrode before calibration.• Before the first use.• Before use after storage for 2 weeks or longer.• If the electrode is less responsive.Calibration:Always calibrate with at least 2 calibration solutions which are 1 decade apart and bracket the expected measurement value.Use fresh calibration solutions and do not re-use them.• Below 10 ppm (mg/L)First solution between 1 and 10ppmSecond solution between 10 and 50 ppm• Between 10 and 100 ppm (mg/L)First solution between 10 and 100ppmSecond solution between 100 and 1000 ppm• Above 100 ppm (mg/L)First solution between 100 and 1000ppmSecond solution above 1000 ppmFurther documentation can be found in the download area of our store Manufacturer article number: 3200986787 (300-NA-C)