Horiba
HORIBA Conductivity & TDS Calibration Solutions – Accurate Calibration from the HeylNeomeris Product Portfolio
Accurate measurement of electrical conductivity (EC) and total dissolved solids (TDS) is essential in many areas of analysis – from water treatment and food safety to environmental monitoring and industrial process control. Regular calibration of measurement devices with appropriate standards is vital for reliable results. In the HeylNeomeris product portfolio, you will find a comprehensive range of HORIBA conductivity and TDS calibration solutions, known for their precision and ease of use.
Why are EC and TDS calibration solutions important?
- Water and Environmental Analysis: Conductivity is a key indicator of the mineral and ion content in water – from drinking water to surface waters and wastewater.
- Food Industry: In the production and quality control – e.g., for beverages, dairy, or fermented products – EC and TDS values provide critical insights into product consistency and hygiene.
- Agriculture & Hydroponics: The availability of nutrients in soil and nutrient solutions can be precisely monitored using conductivity.
- Industrial Processes: In electroplating, chemical manufacturing, or energy production, EC/TDS measurements help in the control and monitoring of critical process parameters.
- Research & Education: Calibration solutions are used in schools, laboratories, and universities for practical training and accurate measurement experiments.
- All Products
- Parameter
- Applications
- Application examples
- Quality
- Brand
-
Buffer and calibration solutions
- pH buffer solutions
- ORP buffer solutions
- Conductivity + TDS calibration solutions
- Storage solutions (KCL)
- Cleaning solutions
- NaCl Standard Solution
- Ammonium Ion Standard Solution
- Calcium Ion Standard Solution
- Chloride Ion Standard Solution
- Fluoride Ion Standard Solution
- Sodium Ion Standard Solution
- Nitrate Ion Standard Solution
- Potassium Ion Standard Solution
- others
- Spare parts and single components
- Plant analysis - sodium, nitrate, potassium, calcium
- Laboratory Benchtop Meters
- Accessories
Filter products
The HORIBA 12.9 mS/cm conductivity standard solution is a reliable calibration solution for high-quality LAQUAtwin EC conductivity meters. This standard solution is precisely preset to a conductivity of 12.9 mS/cm, ensuring fast and reliable calibration of your measuring instruments. Areas of application Ideal for regular calibration and quality control in laboratories, environmental analysis and industrial processes, especially in combination with HORIBA LAQUAtwin EC series instruments. Product advantages at a glance Precise and reproducible conductivity of 12.9 mS/cmSuitable for HORIBA LAQUAtwin EC measuring devicesEasy to use: ready to use, preconfiguredBottle size 14 ml: practical and handy Manufacturer item number: 3999960111
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3999960110
514-4EC-CON Conditioning Solution – For LAQUAtwin 4EC-11, 4EC-22, 4EC-33 and 4ECSalt-11 To ensure the precise calibration and maintenance of HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special range of buffer, calibration and standard solutions. The 514-4EC-CON conditioning solution ensures that your 4EC Pocket Tester is optimally prepared by activating the sensor surface and creating stable measurement conditions. Furthermore, regular use of the solution helps to extend the electrode’s service life and prevent measurement deviations. This ensures that the measured conductivity values are always reliable and meaningful. A practical pack size of 6 x 14 ml of these solutions meets the requirements of the Pocket Tester, as only a few drops are needed for calibration. This pack size helps to reduce waste and increase efficiency during regular calibrations. With these specialised solutions, the HORIBA LAQUAtwin Pocket Testers always deliver accurate and reliable measurement results. The integrity of your measurement data and the service life of your equipment can be ensured through regular calibration using these specially formulated solutions. It is particularly important to select the correct calibration and standard solution in order to maintain measurement accuracy and ensure the reliability of water quality checks in various applications. Note: Conditioning solution 514-4EC-CON is only suitable for the LAQUAtwin 4EC-11, 4EC-22, 4EC-33 and 4ECSalt-11 testers. Manufacturer’s item number: 3201081522
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester. Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely. NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement. Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm). Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm. TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements. ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Important note regarding compatibility Please note: The replacement sensors, both old and new, are not compatible with one another. Similarly, the conditioning solutions for the old and new versions are not compatible with the respective device models. How can you tell if you have an older or a new device? If your Pocket Tester is marked ‘4-cell’, you have the latest version of this device. In this case, you will need the replacement sensors listed in the cross-selling section, as well as the standard and conditioning solutions. These have been specially optimised for the new Pocket Testers and are not suitable for the older models. Manufacturer Part No.: 3999960114
This set contains the following conductivity calibration solutions:1x 84 uS/cm (60 ml) 1x 1413 uS/cm (60 ml)1x 12.88 mS/cm (60 ml)1x 111.8 mS/cm (60 ml)Manufacturer article number: 3200820791