To ensure proper commissioning as well as highly accurate measurement, the use of calibration solutions is essential. Regular calibration ensures that the medium to be monitored is measured reliably. The frequency depends in particular on the operating conditions and the respective process requirements. Proper calibration can compensate for changes in the probe over time, which can be caused by minor damage or contamination, for example.
When selecting a probe, it is important to ensure that:
- The solution selected matches the measuring range of the instrument used.
- The solution used best matches the range in which measurements are to be made.
- In the case of a multi-point calibration, make sure that calibration solutions are used whose values are above and below the required measuring range.
All solutions offered are traceable to the certified international standard SRM NIST.
- All Products
- Parameter
- Applications
- Application examples
- Quality
- Brand
-
Buffer and calibration solutions
- pH buffer solutions
- ORP buffer solutions
- Conductivity + TDS calibration solutions
- Storage solutions (KCL)
- Cleaning solutions
- NaCl Standard Solution
- Ammonium Ion Standard Solution
- Calcium Ion Standard Solution
- Chloride Ion Standard Solution
- Fluoride Ion Standard Solution
- Sodium Ion Standard Solution
- Nitrate Ion Standard Solution
- Potassium Ion Standard Solution
- others
- Spare parts and single components
- Plant analysis - sodium, nitrate, potassium, calcium
- Laboratory Benchtop Meters
- Accessories
Filter products
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications.
HORIBA Ion standard solutions, ionic strength controllers and ion-selective electrode filling solutions are indispensable for accurate and reproducible measurements with ion-selective electrodes (ISE). A large number of analyses in laboratories and in the field, such as testing water and wastewater quality, environmental monitoring and quality control in industrial processes, rely on these solutions. Ionic standard solutions are used to calibrate ion-selective electrodes and ensure precise measurement. Horiba's standard solutions have a known ion concentration. They are therefore essential for setting up the electrodes correctly before using them for test runs. Ionic strength controllers are specifically designed to adjust the ionic strength of the sample to enable accurate measurements. They are particularly important when the composition of the samples could affect the measurement or in samples with low ionic strength. The ionic strength can be adjusted to stabilize the ionic activity in the solution. This leads to more accurate measurement results. Ion-selective electrode filling solutionsIon-selective electrode filling solutions are specific solutions that are filled into ion-selective electrodes. They ensure the proper operation of the electrode and help to maintain the potential required to measure the specific ion. To ensure that measurements meet international standards and to ensure conformity with regulatory and compliance standards, these specialized solutions are essential. Many industries, from pharmaceutical to environmental, use these solutions to meet their quality and safety requirements. For users working in areas such as water analysis, environmental monitoring or regulatory testing environments, these solutions ensure the accuracy and reliability required for critical measurements. To provide reliable data for important environmental, health and safety decisions, they are a crucial part of analytical chemistry. Overall, HORIBA's solutions enable experts to make the best use of their instruments and achieve the precise results required for their applications. Manufacturer article number: 3200697173 (500-NH3-IFS)
HORIBA Ion standard solutions, ionic strength controllers and ion-selective electrode filling solutions are indispensable for accurate and reproducible measurements with ion-selective electrodes (ISE). A large number of analyses in laboratories and in the field, such as testing water and wastewater quality, environmental monitoring and quality control in industrial processes, rely on these solutions. Ionic standard solutions are used to calibrate ion-selective electrodes and ensure precise measurement. Horiba's standard solutions have a known ion concentration. They are therefore essential for setting up the electrodes correctly before using them for test runs. Ionic strength controllers are specifically designed to adjust the ionic strength of the sample to enable accurate measurements. They are particularly important when the composition of the samples could affect the measurement or in samples with low ionic strength. The ionic strength can be adjusted to stabilize the ionic activity in the solution. This leads to more accurate measurement results. Ion-selective electrode filling solutionsIon-selective electrode filling solutions are specific solutions that are filled into ion-selective electrodes. They ensure the proper operation of the electrode and help to maintain the potential required to measure the specific ion. To ensure that measurements meet international standards and to ensure conformity with regulatory and compliance standards, these specialized solutions are essential. Many industries, from pharmaceutical to environmental, use these solutions to meet their quality and safety requirements. For users working in areas such as water analysis, environmental monitoring or regulatory testing environments, these solutions ensure the accuracy and reliability required for critical measurements. To provide reliable data for important environmental, health and safety decisions, they are a crucial part of analytical chemistry. Overall, HORIBA's solutions enable experts to make the best use of their instruments and achieve the precise results required for their applications. Manufacturer article number: 3200697177 (500-CA-IFS)
HORIBA Ion standard solutions, ionic strength controllers and ion-selective electrode filling solutions are indispensable for accurate and reproducible measurements with ion-selective electrodes (ISE). A large number of analyses in laboratories and in the field, such as testing water and wastewater quality, environmental monitoring and quality control in industrial processes, rely on these solutions. Ionic standard solutions are used to calibrate ion-selective electrodes and ensure precise measurement. Horiba's standard solutions have a known ion concentration. They are therefore essential for setting up the electrodes correctly before using them for test runs. Ionic strength controllers are specifically designed to adjust the ionic strength of the sample to enable accurate measurements. They are particularly important when the composition of the samples could affect the measurement or in samples with low ionic strength. The ionic strength can be adjusted to stabilize the ionic activity in the solution. This leads to more accurate measurement results. Ion-selective electrode filling solutionsIon-selective electrode filling solutions are specific solutions that are filled into ion-selective electrodes. They ensure the proper operation of the electrode and help to maintain the potential required to measure the specific ion. To ensure that measurements meet international standards and to ensure conformity with regulatory and compliance standards, these specialized solutions are essential. Many industries, from pharmaceutical to environmental, use these solutions to meet their quality and safety requirements. For users working in areas such as water analysis, environmental monitoring or regulatory testing environments, these solutions ensure the accuracy and reliability required for critical measurements. To provide reliable data for important environmental, health and safety decisions, they are a crucial part of analytical chemistry. Overall, HORIBA's solutions enable experts to make the best use of their instruments and achieve the precise results required for their applications. Manufacturer article number:3200697178 (500-CA-ISA)
514-4EC-CON Conditioning Solution – For LAQUAtwin 4EC-11, 4EC-22, 4EC-33 and 4ECSalt-11 To ensure the precise calibration and maintenance of HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special range of buffer, calibration and standard solutions. The 514-4EC-CON conditioning solution ensures that your 4EC Pocket Tester is optimally prepared by activating the sensor surface and creating stable measurement conditions. Furthermore, regular use of the solution helps to extend the electrode’s service life and prevent measurement deviations. This ensures that the measured conductivity values are always reliable and meaningful. A practical pack size of 6 x 14 ml of these solutions meets the requirements of the Pocket Tester, as only a few drops are needed for calibration. This pack size helps to reduce waste and increase efficiency during regular calibrations. With these specialised solutions, the HORIBA LAQUAtwin Pocket Testers always deliver accurate and reliable measurement results. The integrity of your measurement data and the service life of your equipment can be ensured through regular calibration using these specially formulated solutions. It is particularly important to select the correct calibration and standard solution in order to maintain measurement accuracy and ensure the reliability of water quality checks in various applications. Note: Conditioning solution 514-4EC-CON is only suitable for the LAQUAtwin 4EC-11, 4EC-22, 4EC-33 and 4ECSalt-11 testers. Manufacturer’s item number: 3201081522
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester. Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely. NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement. Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm). Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm. TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements. ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Important note regarding compatibility Please note: The replacement sensors, both old and new, are not compatible with one another. Similarly, the conditioning solutions for the old and new versions are not compatible with the respective device models. How can you tell if you have an older or a new device? If your Pocket Tester is marked ‘4-cell’, you have the latest version of this device. In this case, you will need the replacement sensors listed in the cross-selling section, as well as the standard and conditioning solutions. These have been specially optimised for the new Pocket Testers and are not suitable for the older models. Manufacturer Part No.: 3999960114
HORIBA Ion standard solutions, ionic strength controllers and ion-selective electrode filling solutions are indispensable for accurate and reproducible measurements with ion-selective electrodes (ISE). A large number of analyses in laboratories and in the field, such as testing water and wastewater quality, environmental monitoring and quality control in industrial processes, rely on these solutions. Ionic standard solutions are used to calibrate ion-selective electrodes and ensure precise measurement. Horiba's standard solutions have a known ion concentration. They are therefore essential for setting up the electrodes correctly before using them for test runs. Ionic strength controllers are specifically designed to adjust the ionic strength of the sample to enable accurate measurements. They are particularly important when the composition of the samples could affect the measurement or in samples with low ionic strength. The ionic strength can be adjusted to stabilize the ionic activity in the solution. This leads to more accurate measurement results. Ion-selective electrode filling solutionsIon-selective electrode filling solutions are specific solutions that are filled into ion-selective electrodes. They ensure the proper operation of the electrode and help to maintain the potential required to measure the specific ion. To ensure that measurements meet international standards and to ensure conformity with regulatory and compliance standards, these specialized solutions are essential. Many industries, from pharmaceutical to environmental, use these solutions to meet their quality and safety requirements. For users working in areas such as water analysis, environmental monitoring or regulatory testing environments, these solutions ensure the accuracy and reliability required for critical measurements. To provide reliable data for important environmental, health and safety decisions, they are a crucial part of analytical chemistry. Overall, HORIBA's solutions enable experts to make the best use of their instruments and achieve the precise results required for their applications. Manufacturer article number: 3200697165 (500-F-IFS)
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200991632
HORIBA Ion standard solutions, ionic strength controllers and ion-selective electrode filling solutions are indispensable for accurate and reproducible measurements with ion-selective electrodes (ISE). A large number of analyses in laboratories and in the field, such as testing water and wastewater quality, environmental monitoring and quality control in industrial processes, rely on these solutions. Ionic standard solutions are used to calibrate ion-selective electrodes and ensure precise measurement. Horiba's standard solutions have a known ion concentration. They are therefore essential for setting up the electrodes correctly before using them for test runs. Ionic strength controllers are specifically designed to adjust the ionic strength of the sample to enable accurate measurements. They are particularly important when the composition of the samples could affect the measurement or in samples with low ionic strength. The ionic strength can be adjusted to stabilize the ionic activity in the solution. This leads to more accurate measurement results. Ion-selective electrode filling solutionsIon-selective electrode filling solutions are specific solutions that are filled into ion-selective electrodes. They ensure the proper operation of the electrode and help to maintain the potential required to measure the specific ion. To ensure that measurements meet international standards and to ensure conformity with regulatory and compliance standards, these specialized solutions are essential. Many industries, from pharmaceutical to environmental, use these solutions to meet their quality and safety requirements. For users working in areas such as water analysis, environmental monitoring or regulatory testing environments, these solutions ensure the accuracy and reliability required for critical measurements. To provide reliable data for important environmental, health and safety decisions, they are a crucial part of analytical chemistry. Overall, HORIBA's solutions enable experts to make the best use of their instruments and achieve the precise results required for their applications. Manufacturer article number:3200697166 (500-F-TISAB)
Optimal Measurement Conditions for Precise and Reproducible Ammonium Analysis Ionic strength adjuster for stabilizing the measurement matrix and reducing matrix-related deviations in ion-selective ammonium measurements With the Horiba Ionic Ammonium Strength Adjuster, users receive a reliable ionic strength adjuster for professional ammonium measurements. The product supports a stable electrochemical measurement environment and helps ensure that results are more precise and comparable. abc-ISA is therefore the ideal addition for all applications requiring accurate ammonium determination. The Ionic Ammonium Strength Adjuster is a high-quality solution for reliable and reproducible determination of ammonium using ion-selective electrodes. It creates a defined measurement matrix, improves comparability between samples and calibration solutions, and supports stable and accurate results. Especially with varying sample compositions, the adjuster helps reduce matrix-related measurement deviations. By specifically adjusting ionic strength, the Horiba Ionic Ammonium Strength Adjuster creates optimal conditions for ammonium analysis in laboratory work, environmental analysis, water testing, and process control. The application is simple and supports efficient sample preparation in routine operations. Advantages of the Horiba Ionic Ammonium Strength Adjuster Suitable for ammonium measurements with ion-selective sensors. Ensures constant ionic strength in samples and standards. Improves reproducibility and measurement accuracy. Reduces matrix effects and interfering influences. Ideal for laboratory, analytics, water testing, and quality control. Typical Applications for the Ammonium Strength Adjuster Ammonium determination in laboratories. Water and wastewater analysis. Environmental analysis. Process and quality control. Routine analysis with ion-selective electrodes. Manufacturer article number: 3200987466 (500-NH4-ISA)
Manufacturer article number: 3200987465 (500-NA-ISA)
Horiba cleaning solution for removing protein and blood residues on the ion-selective sensors of the LAQUAtwin testers. Why blood? This passage was included due to the calcium animal blood LAQUAtwin tester available on request (calcium ion sensor S051). Manufacturer article number: 3200774601 (S051) Additional information We would like to inform you of an upcoming product update for the LAQUAtwin handheld analysers. To enhance product safety and prevent infants and young children from accidentally swallowing the batteries, HORIBA will be introducing a new battery cover on all LAQUAtwin pocket-sized analysers. Overview of the product change Change: Battery cover for enhanced safety. Reason: To prevent accidental swallowing of batteries. Production date: From January 2026 in Japan Deliveries to EMEA distribution partners: From March 2026 As this change is currently being rolled out, mixed deliveries of the current and updated versions may occur during the transition period.
HORIBA Ion standard solutions, ionic strength controllers and ion-selective electrode filling solutions are indispensable for accurate and reproducible measurements with ion-selective electrodes (ISE). A large number of analyses in laboratories and in the field, such as testing water and wastewater quality, environmental monitoring and quality control in industrial processes, rely on these solutions. Ionic standard solutions are used to calibrate ion-selective electrodes and ensure precise measurement. Horiba's standard solutions have a known ion concentration. They are therefore essential for setting up the electrodes correctly before using them for test runs. Ionic strength controllers are specifically designed to adjust the ionic strength of the sample to enable accurate measurements. They are particularly important when the composition of the samples could affect the measurement or in samples with low ionic strength. The ionic strength can be adjusted to stabilize the ionic activity in the solution. This leads to more accurate measurement results. Ion-selective electrode filling solutionsIon-selective electrode filling solutions are specific solutions that are filled into ion-selective electrodes. They ensure the proper operation of the electrode and help to maintain the potential required to measure the specific ion. To ensure that measurements meet international standards and to ensure conformity with regulatory and compliance standards, these specialized solutions are essential. Many industries, from pharmaceutical to environmental, use these solutions to meet their quality and safety requirements. For users working in areas such as water analysis, environmental monitoring or regulatory testing environments, these solutions ensure the accuracy and reliability required for critical measurements. To provide reliable data for important environmental, health and safety decisions, they are a crucial part of analytical chemistry. Overall, HORIBA's solutions enable experts to make the best use of their instruments and achieve the precise results required for their applications. Manufacturer article number: 3200697181 (500-NO3-IFS)
The original solution should be used as it is. For general use as standard solution sets, 101-S (100-4.7.9 and #310 internal solution) are also available. Manufacturer article number:3200043639 (100-2)
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3999960108
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Article Number: 3200691954
The original solution should be used as it is. For general use as standard solution sets, 101-S (100-4.7.9 and #310 internal solution) are also available. Manufacturer article number:3200043637 (100-7)
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3999960109
The original solution should be used as it is. For general use as standard solution sets, 101-S (100-4.7.9 and #310 internal solution) are also available. Manufacturer article number:3200043636 (100-9)
Horiba pH6.86 (500 ml), pH4 (250 ml) and pH9.18 (250 ml) buffer solution (101-S) Reference electrode Internal solution #300 (250 ml) / dropper Use undiluted.The set contains standard and internal solutions, as shown. Manufacturer article number:3200043642 (101-S)
HORIBA Ion standard solutions, ionic strength controllers and ion-selective electrode filling solutions are indispensable for accurate and reproducible measurements with ion-selective electrodes (ISE). A large number of analyses in laboratories and in the field, such as testing water and wastewater quality, environmental monitoring and quality control in industrial processes, rely on these solutions. Ionic standard solutions are used to calibrate ion-selective electrodes and ensure precise measurement. Horiba's standard solutions have a known ion concentration. They are therefore essential for setting up the electrodes correctly before using them for test runs. Ionic strength controllers are specifically designed to adjust the ionic strength of the sample to enable accurate measurements. They are particularly important when the composition of the samples could affect the measurement or in samples with low ionic strength. The ionic strength can be adjusted to stabilize the ionic activity in the solution. This leads to more accurate measurement results. Ion-selective electrode filling solutionsIon-selective electrode filling solutions are specific solutions that are filled into ion-selective electrodes. They ensure the proper operation of the electrode and help to maintain the potential required to measure the specific ion. To ensure that measurements meet international standards and to ensure conformity with regulatory and compliance standards, these specialized solutions are essential. Many industries, from pharmaceutical to environmental, use these solutions to meet their quality and safety requirements. For users working in areas such as water analysis, environmental monitoring or regulatory testing environments, these solutions ensure the accuracy and reliability required for critical measurements. To provide reliable data for important environmental, health and safety decisions, they are a crucial part of analytical chemistry. Overall, HORIBA's solutions enable experts to make the best use of their instruments and achieve the precise results required for their applications. Manufacturer article number: 3200697185 (500-K-IFS)
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200997084
Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.
Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.