Conductivity and TDS Calibration Solutions are liquids used to ensure the accuracy of devices measuring electrical conductivity (EC) and total dissolved solids (TDS). These solutions provide stable reference values for precise measurements.
Why are they needed?
- Calibration of Conductivity and TDS Sensors: For accurate measurements of conductivity and TDS levels in liquids.
- Water Quality Monitoring: To monitor the quality of water in natural bodies and wastewater.
- Food Industry: To control TDS and conductivity in beverages and liquids.
- Pharmaceutical Applications: For precise TDS measurements in medicines and chemical solutions.
- Aquaristics and Hydroponics: To check the TDS levels and conductivity in aquariums and nutrient solutions.
Conductivity and TDS calibration solutions are essential for reliable measurements and ensuring accuracy in many scientific and industrial applications.
- All Products
- Parameter
- Applications
- Application examples
- Quality
- Brand
-
Buffer and calibration solutions
- pH buffer solutions
- ORP buffer solutions
- Conductivity + TDS calibration solutions
- Storage solutions (KCL)
- Cleaning solutions
- NaCl Standard Solution
- Ammonium Ion Standard Solution
- Calcium Ion Standard Solution
- Chloride Ion Standard Solution
- Fluoride Ion Standard Solution
- Sodium Ion Standard Solution
- Nitrate Ion Standard Solution
- Potassium Ion Standard Solution
- others
- Spare parts and single components
- Plant analysis - sodium, nitrate, potassium, calcium
- Laboratory Benchtop Meters
- Accessories
Filter products
Neomeris conductivity calibration solution 111.8 mS/cm (± 1% at 25 °C) is a high-quality reference solution for calibrating your electrodes and measuring devices. Stable reference solution for demanding conductivity measurements With a defined conductivity value of 111.8 mS/cm (±1% at 25 °C), the calibration solution ensures reliable calibration of electrodes and measuring devices. The hygienic closure protects the solution from contamination and allows clean removal for direct use. In which areas can the solution be used? Water and environmental analysis: Monitoring mineral and ion concentrations to assess water quality. Food and beverage industry: Ensuring product consistency and hygiene through precise conductivity measurements. Agriculture & hydroponics: Monitoring nutrient availability in soils and nutrient solutions. Industrial processes: Process control in electroplating, chemical production and energy generation. Research & education: Reference solution for precise experiments and training. Frequently asked questions Where can I find the safety data sheet for the solution I want to use? The safety data sheet is included in printed form with the delivery of the goods. The safety data sheet can be viewed or downloaded at any time in the download area of the online shop. What bottle sizes are available? Generally, there are 60/70 ml, 250 ml, 500 ml and 1,000 ml bottles. There is one exception, for example, with brands such as Hanna, where bags are sold instead of bottles. How long do the solutions last? The shelf life is printed on the product label. Upon delivery, the shelf life is at least 7 months. Can the solutions still be used after the expiry date? No, because the function and quality can no longer be guaranteed after the best-before date has expired. How can I dispose of the solutions? Please refer to the safety data sheet for more detailed information on the disposal of the solutions. Disposal must be carried out in accordance with official regulations. What is the emergency number for acute poisoning? The emergency number for the North Poison Information Centre is +49 551-19240 and is available 24/7.
This conductivity & TDS calibration solution in a 1000 ml bottle contains enough liquid for multiple calibrations. Thanks to its easy dosing and handling, it can be used quickly and flawlessly in various areas. Neomeris conductivity & TDS calibration solution 147 μS/cm ± 1% (25 °C), 1000 ml – precision for your EC and TDS measuring devices The Neomeris conductivity & TDS calibration solution with a stable reference value of 147 μS/cm ± 1% at 25 °C is specially designed for calibrating measuring devices used to determine electrical conductivity (EC) and total dissolved solids (TDS). It ensures precise and reproducible measurement results in numerous areas – from environmental analysis to industrial process control. Product advantages at a glance: Precise calibration: Constant conductivity value with an accuracy of ± 1% at 25 °C – ideal for precise requirements. Certificate of analysis included: Each 1000 ml bottle comes with a free certificate confirming the quality and accuracy of the solution. Safe handling: The special hygienic cap reliably protects the solution from contamination. Easy dosing: Squeezing the bottle releases the required amount of solution into the upper part – ideal for direct calibration without additional accessories. 1000 ml content: Ideal for regular use in laboratories, businesses and educational institutions with higher consumption. Areas of application: Water and environmental analysis: Monitoring mineral and ion concentrations to assess water quality. Food and beverage industry: Ensuring product consistency and hygiene through precise conductivity measurements. Agriculture & hydroponics: Monitoring nutrient availability in soils and nutrient solutions. Industrial processes: Process control in electroplating, chemical production and energy generation. Research & education: Reference solution for precise experiments and training. Neomeris – For reliable EC and TDS measurements. Rely on quality, safety and traceability – with professional calibration solutions from Neomeris, including a certificate of analysis. With its practical 1000 ml bottle and hygienic dosing system, the Neomeris calibration solution is particularly suitable for regular use in professional environments. Trust in quality, precision and ease of use – for reliable measurement results, day after day. Frequently asked questions Where can I find the safety data sheet for the solution I want to use? The safety data sheet is included in printed form with the delivery of the goods. The safety data sheet can be viewed or downloaded at any time in the download area of the online shop. What bottle sizes are available? Generally, there are 60/70 ml, 250 ml, 500 ml and 1,000 ml bottles. There is one exception, for example, with brands such as Hanna, where bags are sold instead of bottles. How long do the solutions last? The shelf life is printed on the product label. Upon delivery, the shelf life is at least 7 months. Can the solutions still be used after the expiry date? No, because the function and quality can no longer be guaranteed after the best-before date has expired. How can I dispose of the solutions? Please refer to the safety data sheet for more detailed information on the disposal of the solutions. Disposal must be carried out in accordance with official regulations. What is the emergency number for acute poisoning? The emergency number for the North Poison Information Centre is +49 551-19240 and is available 24/7.
High quality conductivity calibration solution to calibrate your electrodes Our 250 ml, 500 ml and 1000 ml bottle is characterized by a special hygienic closure, which protects the conductivity calibration solution from contamination. To provide the required calibration solution, simply squeeze the bottle together and enough conductivity calibration solution is delivered to the upper part of the bottle to perform a calibration. Frequently asked questions Where can I find the safety data sheet for the solution I want to use? The safety data sheet is included in printed form with the delivery of the goods. The safety data sheet can be viewed or downloaded at any time in the download area of the online shop. What bottle sizes are available? Generally, there are 60/70 ml, 250 ml, 500 ml and 1,000 ml bottles. There is one exception, for example, with brands such as Hanna, where bags are sold instead of bottles. How long do the solutions last? The shelf life is printed on the product label. Upon delivery, the shelf life is at least 7 months. Can the solutions still be used after the expiry date? No, because the function and quality can no longer be guaranteed after the best-before date has expired. How can I dispose of the solutions? Please refer to the safety data sheet for more detailed information on the disposal of the solutions. Disposal must be carried out in accordance with official regulations. What is the emergency number for acute poisoning? The emergency number for the North Poison Information Centre is +49 551-19240 and is available 24/7.
The Neomeris conductivity calibration solution is perfect for calibrating your measuring instruments for determining electrical conductivity. It is available in a 1000 ml bottle. NEOMERIS conductivity calibration solution EC 1413 μS/cm – 1413 μS/cm ±1% at 25°C, 1000 ml Reliable calibration for precise EC measurements The Neomeris calibration solution with a defined conductivity value of 1413 μS/cm ±1% at 25°C has been specially developed for the exact calibration of measuring instruments for determining electrical conductivity (EC). It provides stable reference values for precise and reproducible measurement results – indispensable in laboratories, industry and research. Product advantages at a glance: Calibration value: 1413 μS/cm ±1% at 25°C Contents: 1000 ml Hygienic closure: Innovative dosing mechanism protects against contamination and enables easy, clean removal Certificate of analysis included: For maximum transparency and quality assurance Why is a calibration solution essential? Measuring devices can change due to use, deposits or temperature fluctuations. Without regular calibration, the values displayed are often no longer accurate. With a reference solution, you can check your device and adjust it correctly. What is the conductivity calibration solution suitable or unsuitable for? The solution is suitable for conductivity measuring devices that can be set to this calibration value. It is not suitable for other water analyses or as a measuring sample itself. Typical areas of application for a conductivity calibration solution (EC 1413 µS/cm) are: Calibration of conductivity meters (EC meters) Checking the measuring accuracy of probes and electrodes The 1413 µS/cm solution is a commonly used standard in the medium conductivity range. With its practical 1000 ml bottle and hygienic dosing system, the Neomeris calibration solution is particularly suitable for regular use in professional environments. Trust in quality, precision and ease of use – for reliable measurement results, day after day. Frequently asked questions Where can I find the safety data sheet for the solution I want to use? The safety data sheet is included in printed form with the delivery of the goods. The safety data sheet can be viewed or downloaded at any time in the download area of the online shop. What bottle sizes are available? Generally, there are 60/70 ml, 250 ml, 500 ml and 1,000 ml bottles. There is one exception, for example, with brands such as Hanna, where bags are sold instead of bottles. How long do the solutions last? The shelf life is printed on the product label. Upon delivery, the shelf life is at least 7 months. Can the solutions still be used after the expiry date? No, because the function and quality can no longer be guaranteed after the best-before date has expired. How can I dispose of the solutions? Please refer to the safety data sheet for more detailed information on the disposal of the solutions. Disposal must be carried out in accordance with official regulations. What is the emergency number for acute poisoning? The emergency number for the North Poison Information Centre is +49 551-19240 and is available 24/7.
This Neomeris conductivity & TDS calibration solution ensures precise measurements in many areas of application. Thanks to its easy dosing and safe handling, you can calibrate your measuring devices quickly and easily. Neomeris Conductivity & TDS Calibration Solution 84 μS/cm ± 1% (25 °C), 1000 ml - Precise calibration for reliable EC and TDS measurements The Neomeris conductivity & TDS calibration solution with a stable reference value of 84 μS/cm ± 1% at 25 °C is specially designed for calibrating measuring devices used to determine electrical conductivity (EC) and total dissolved solids (TDS). It ensures precise and reproducible measurement results in numerous areas of application – from environmental analysis to industrial process control. Product advantages at a glance: Precise calibration: Constant conductivity value with an accuracy of ± 1 % at 25 °C – ideal for precise requirements. Certificate of analysis included: Each 1000 ml bottle comes with a free certificate confirming the quality and accuracy of the solution. Safe handling: The innovative hygienic cap reliably protects the solution from contamination. Easy dosing: Squeezing the bottle releases the required amount of solution into the upper part – ideal for direct calibration without additional accessories. 1000 ml content: Ideal for regular use in laboratories, businesses, and educational institutions with higher consumption. Areas of application: Water and environmental analysis: Evaluation of water quality by monitoring mineral and ion concentrations. Food and beverage industry: Ensuring product consistency and hygiene through precise conductivity measurements. Agriculture & hydroponics: Monitoring nutrient availability in soils and nutrient solutions. Industrial processes: Monitoring in electroplating, chemical production, and energy generation. Research & teaching: Reference solution for precise experiments and training. Neomeris – For reliable EC and TDS measurements. Rely on quality, safety, and verifiability – with professional calibration solutions from Neomeris, including a certificate of analysis. With its practical 1000 ml bottle and hygienic dosing system, the Neomeris calibration solution is particularly suitable for regular use in professional environments. Trust in quality, precision, and ease of use – for reliable measurement results, day after day.
XS Professional conductivity calibration solution for electrode calibration The 250 ml and 500 ml bottles have a practical hygienic cap which protects against contamination. Simply squeeze the bottle and sufficient conductivity calibration solution is automatically delivered to the top of the bottle for calibration. Supplied with DFM certificate (equivalent to Accredia) and N.I.S.T. traceability
XS Professional conductivity calibration solution for electrode calibration The 250 ml and 500 ml bottles have a practical hygienic cap which protects against contamination. Simply squeeze the bottle and sufficient conductivity calibration solution is automatically delivered to the top of the bottle for calibration. Supplied with DFM certificate (equivalent to Accredia) and N.I.S.T. traceability
XS Professional conductivity calibration solution for electrode calibration The 250 ml and 500 ml bottles have a practical hygienic cap which protects against contamination. Simply squeeze the bottle and sufficient conductivity calibration solution is automatically delivered to the top of the bottle for calibration. Supplied with DFM certificate (equivalent to Accredia) and N.I.S.T. traceability
XS Professional conductivity calibration solution for electrode calibration The 250 ml and 500 ml bottles have a practical hygienic cap which protects against contamination. Simply squeeze the bottle and sufficient conductivity calibration solution is automatically delivered to the top of the bottle for calibration. Supplied with DFM certificate (equivalent to Accredia) and N.I.S.T. traceability
Explore HORIBA's premium profile solutions for pH, ORP and conductivity measurements, specifically designed for handheld and laboratory meters. Our solutions are designed to meet the needs of different users and ensure that your measurements are accurate. Here are a few of our products that provide a clear overview and easy selection: - pH standard solutions are available in different pH value classes: e.g. 4.01, 7.00, 10.01. These solutions are indispensable for the calibration of pH electrodes and have a high degree of accuracy. - Redox standard solutions (ORP): These solutions offer values from 200 mV to 650 mV, enabling precise adjustment of redox electrodes. Standard solutions for conductivity: These are used to calibrate conductivity sensors and are available in different conductivity ranges. - Internal filling solutions: These solutions are specially designed for pH and reference electrodes and ensure optimum functionality as well as a long service life for your electrodes. Users:- Our NIST-traceable hygienic bottle solutions are ideal for environmental laboratories using pH and ORP buffer solutions to monitor water quality in natural waters. They enable safe and accurate calibration without the risk of contamination. - Our buffer solutions provide a reliable basis for compliant results in the pharmaceutical industry, where accurate pH measurements are critical for drug formulation and quality control. - Our pH and redox solutions are of great importance to the food and beverage industry and play a crucial role in the quality of products, from wine production to milk processing. - Our solutions are used by research institutions and universities to conduct their scientific experiments and train the next generation of scientists. - Our conductivity standard solutions are used by water treatment plants to improve their purification and filtration processes. Manufacturer information: Because HORIBA is synonymous with quality and precision, you can trust our professional solutions to complement your measurement equipment and extend its life. HORIBA's innovative hygienic bottles differ significantly from conventional bottles as they allow contamination-free removal by simply squeezing. As the lower part of the bottle always remains fresh and untouched, it is particularly advantageous for applications where cleanliness and accuracy are crucial. Use HORIBA solutions to ensure the accuracy of your measurements and promote the functionality of your measuring devices. HORIBA high quality conductivity calibration solution to calibrate your electrodes The 250 ml, 500 ml and 1000 ml bottle is characterized by a special hygienic closure, which protects the conductivity calibration solution from contamination. To provide the required calibration solution, simply squeeze the bottle together and enough conductivity calibration solution is delivered to the upper part of the bottle to perform a calibration.
Explore HORIBA's premium profile solutions for pH, ORP and conductivity measurements, specifically designed for handheld and laboratory meters. Our solutions are designed to meet the needs of different users and ensure that your measurements are accurate. Here are a few of our products that provide a clear overview and easy selection: - pH standard solutions are available in different pH value classes: e.g. 4.01, 7.00, 10.01. These solutions are indispensable for the calibration of pH electrodes and have a high degree of accuracy. - Redox standard solutions (ORP): These solutions offer values from 200 mV to 650 mV, enabling precise adjustment of redox electrodes. Standard solutions for conductivity: These are used to calibrate conductivity sensors and are available in different conductivity ranges. - Internal filling solutions: These solutions are specially designed for pH and reference electrodes and ensure optimum functionality as well as a long service life for your electrodes. Users:- Our NIST-traceable hygienic bottle solutions are ideal for environmental laboratories using pH and ORP buffer solutions to monitor water quality in natural waters. They enable safe and accurate calibration without the risk of contamination. - Our buffer solutions provide a reliable basis for compliant results in the pharmaceutical industry, where accurate pH measurements are critical for drug formulation and quality control. - Our pH and redox solutions are of great importance to the food and beverage industry and play a crucial role in the quality of products, from wine production to milk processing. - Our solutions are used by research institutions and universities to conduct their scientific experiments and train the next generation of scientists. - Our conductivity standard solutions are used by water treatment plants to improve their purification and filtration processes. Manufacturer information: Because HORIBA is synonymous with quality and precision, you can trust our professional solutions to complement your measurement equipment and extend its life. HORIBA's innovative hygienic bottles differ significantly from conventional bottles as they allow contamination-free removal by simply squeezing. As the lower part of the bottle always remains fresh and untouched, it is particularly advantageous for applications where cleanliness and accuracy are crucial. Use HORIBA solutions to ensure the accuracy of your measurements and promote the functionality of your measuring devices. HORIBA high quality conductivity calibration solution to calibrate your electrodes The 250 ml, 500 ml and 1000 ml bottle is characterized by a special hygienic closure, which protects the conductivity calibration solution from contamination. To provide the required calibration solution, simply squeeze the bottle together and enough conductivity calibration solution is delivered to the upper part of the bottle to perform a calibration.
Explore HORIBA's premium profile solutions for pH, ORP and conductivity measurements, specifically designed for handheld and laboratory meters. Our solutions are designed to meet the needs of different users and ensure that your measurements are accurate. Here are a few of our products that provide a clear overview and easy selection: - pH standard solutions are available in different pH value classes: e.g. 4.01, 7.00, 10.01. These solutions are indispensable for the calibration of pH electrodes and have a high degree of accuracy. - Redox standard solutions (ORP): These solutions offer values from 200 mV to 650 mV, enabling precise adjustment of redox electrodes. Standard solutions for conductivity: These are used to calibrate conductivity sensors and are available in different conductivity ranges. - Internal filling solutions: These solutions are specially designed for pH and reference electrodes and ensure optimum functionality as well as a long service life for your electrodes. Users:- Our NIST-traceable hygienic bottle solutions are ideal for environmental laboratories using pH and ORP buffer solutions to monitor water quality in natural waters. They enable safe and accurate calibration without the risk of contamination. - Our buffer solutions provide a reliable basis for compliant results in the pharmaceutical industry, where accurate pH measurements are critical for drug formulation and quality control. - Our pH and redox solutions are of great importance to the food and beverage industry and play a crucial role in the quality of products, from wine production to milk processing. - Our solutions are used by research institutions and universities to conduct their scientific experiments and train the next generation of scientists. - Our conductivity standard solutions are used by water treatment plants to improve their purification and filtration processes. Manufacturer information: Because HORIBA is synonymous with quality and precision, you can trust our professional solutions to complement your measurement equipment and extend its life. HORIBA's innovative hygienic bottles differ significantly from conventional bottles as they allow contamination-free removal by simply squeezing. As the lower part of the bottle always remains fresh and untouched, it is particularly advantageous for applications where cleanliness and accuracy are crucial. Use HORIBA solutions to ensure the accuracy of your measurements and promote the functionality of your measuring devices. HORIBA high quality conductivity calibration solution to calibrate your electrodes The 250 ml, 500 ml and 1000 ml bottle is characterized by a special hygienic closure, which protects the conductivity calibration solution from contamination. To provide the required calibration solution, simply squeeze the bottle together and enough conductivity calibration solution is delivered to the upper part of the bottle to perform a calibration.
Explore HORIBA's premium profile solutions for pH, ORP and conductivity measurements, specifically designed for handheld and laboratory meters. Our solutions are designed to meet the needs of different users and ensure that your measurements are accurate. Here are a few of our products that provide a clear overview and easy selection: - pH standard solutions are available in different pH value classes: e.g. 4.01, 7.00, 10.01. These solutions are indispensable for the calibration of pH electrodes and have a high degree of accuracy. - Redox standard solutions (ORP): These solutions offer values from 200 mV to 650 mV, enabling precise adjustment of redox electrodes. Standard solutions for conductivity: These are used to calibrate conductivity sensors and are available in different conductivity ranges. - Internal filling solutions: These solutions are specially designed for pH and reference electrodes and ensure optimum functionality as well as a long service life for your electrodes. Users:- Our NIST-traceable hygienic bottle solutions are ideal for environmental laboratories using pH and ORP buffer solutions to monitor water quality in natural waters. They enable safe and accurate calibration without the risk of contamination. - Our buffer solutions provide a reliable basis for compliant results in the pharmaceutical industry, where accurate pH measurements are critical for drug formulation and quality control. - Our pH and redox solutions are of great importance to the food and beverage industry and play a crucial role in the quality of products, from wine production to milk processing. - Our solutions are used by research institutions and universities to conduct their scientific experiments and train the next generation of scientists. - Our conductivity standard solutions are used by water treatment plants to improve their purification and filtration processes. Manufacturer information: Because HORIBA is synonymous with quality and precision, you can trust our professional solutions to complement your measurement equipment and extend its life. HORIBA's innovative hygienic bottles differ significantly from conventional bottles as they allow contamination-free removal by simply squeezing. As the lower part of the bottle always remains fresh and untouched, it is particularly advantageous for applications where cleanliness and accuracy are crucial. Use HORIBA solutions to ensure the accuracy of your measurements and promote the functionality of your measuring devices. HORIBA high quality conductivity calibration solution to calibrate your electrodes The 250 ml, 500 ml and 1000 ml bottle is characterized by a special hygienic closure, which protects the conductivity calibration solution from contamination. To provide the required calibration solution, simply squeeze the bottle together and enough conductivity calibration solution is delivered to the upper part of the bottle to perform a calibration.
This set contains the following conductivity calibration solutions:1x 84 uS/cm (60 ml) 1x 1413 uS/cm (60 ml)1x 12.88 mS/cm (60 ml)1x 111.8 mS/cm (60 ml)Manufacturer article number: 3200820791
XS Professional conductivity calibration solution for electrode calibration The 250 ml and 500 ml bottles have a practical hygienic cap which protects against contamination. Simply squeeze the bottle and sufficient conductivity calibration solution is automatically delivered to the top of the bottle for calibration. Supplied with DFM certificate (equivalent to Accredia) and N.I.S.T. traceability
XS Professional conductivity calibration solution for electrode calibration The 250 ml and 500 ml bottles have a practical hygienic cap which protects against contamination. Simply squeeze the bottle and sufficient conductivity calibration solution is automatically delivered to the top of the bottle for calibration. Supplied with DFM certificate (equivalent to Accredia) and N.I.S.T. traceability
XS Professional conductivity calibration solution for electrode calibration The 250 ml and 500 ml bottles have a practical hygienic cap which protects against contamination. Simply squeeze the bottle and sufficient conductivity calibration solution is automatically delivered to the top of the bottle for calibration. Supplied with DFM certificate (equivalent to Accredia) and N.I.S.T. traceability
XS Professional conductivity calibration solution for electrode calibration The 250 ml and 500 ml bottles have a practical hygienic cap which protects against contamination. Simply squeeze the bottle and sufficient conductivity calibration solution is automatically delivered to the top of the bottle for calibration. Supplied with DFM certificate (equivalent to Accredia) and N.I.S.T. traceability
Manufacturer number: 51102063XS BASIC calibration solutions in sachetsSingle buffer (no different measuring ranges)with N.I.S.T. traceability
XS Professional conductivity calibration solution for electrode calibration The 250 ml and 500 ml bottles have a practical hygienic cap which protects against contamination. Simply squeeze the bottle and sufficient conductivity calibration solution is automatically delivered to the top of the bottle for calibration. Supplied with DFM certificate (equivalent to Accredia) and N.I.S.T. traceability
XS Professional conductivity calibration solution for electrode calibration The 250 ml and 500 ml bottles have a practical hygienic cap which protects against contamination. Simply squeeze the bottle and sufficient conductivity calibration solution is automatically delivered to the top of the bottle for calibration. Supplied with DFM certificate (equivalent to Accredia) and N.I.S.T. traceability
XS Professional conductivity calibration solution for electrode calibration The 250 ml and 500 ml bottles have a practical hygienic cap which protects against contamination. Simply squeeze the bottle and sufficient conductivity calibration solution is automatically delivered to the top of the bottle for calibration. Supplied with DFM certificate (equivalent to Accredia) and N.I.S.T. traceability
Manufacturer number: 51102053XS BASIC calibration solutions in sachetsSingle buffer (no different measuring ranges)with N.I.S.T. traceability
XS Professional conductivity calibration solution for electrode calibration The 250 ml and 500 ml bottles have a practical hygienic cap which protects against contamination. Simply squeeze the bottle and sufficient conductivity calibration solution is automatically delivered to the top of the bottle for calibration. Supplied with DFM certificate (equivalent to Accredia) and N.I.S.T. traceability