In our online shop we offer you a broad product portfolio of various pocket testers. You can select the right pocket tester for you according to various criteria: measurement parameters, application area, quality features or manufacturer.
With the uncomplicated to handle portable analyzers, the measurement of viscous liquids, solids and even powder samples is possible. Only a few drops of the standard solution or sample on the highly sensitive sensor are required to obtain fast and reliable test results. This procedure saves you time and, in addition to industrial use, also allows the handheld meters to be used in the home.
At the same time, the integrated analysis function, the large illuminated display and the replaceable batteries make the handheld analyzer from Horiba very user-friendly.
Our instruments are used, among others, in:
- Water or liquid analysis
- Conformity testing
- Food or environmental analysis
- Quality control
- Biotechnology
Choose your pocket tester from the different brands:
- Horiba
- Milwaukee
- XS Instruments
Filter products
The HORIBA LAQUAtwin Pocket Testers provide a comprehensive solution for immediate and precise measurement of water quality parameters directly in the field. To ensure that these measurements remain reliable and accurate, it is essential to regularly check the sensors and replace them with spare sensors if necessary. The replacement sensors, developed specifically for the HORIBA LAQUAtwin series, cover a variety of types for different measurements: pH, conductivity, salinity, redox (ORP), as well as ion-selective sensors for sodium, potassium, nitrate, calcium, and fluoride. Each of these sensors is designed to maximize user-friendliness and precision, qualities for which HORIBA is globally recognized in water quality testing. HORIBA replacement sensors ensure that users’ devices consistently deliver optimal performance and accurate measurements. Advantages of HORIBA Replacement Sensors: Easy Replacement: Sensors can be replaced quickly, allowing measurements to continue without delay. High Precision: Replacement sensors ensure results are accurate and reliable. Comprehensive Measurement Range: Various sensor types are available to measure a wide range of water quality parameters. Durability: Sensors are designed for long service life even under challenging conditions. Sensor Replacement Instructions: To ensure the longevity and accuracy of your HORIBA LAQUAtwin Pocket Tester, follow these steps when replacing a sensor: Removing the Sensor: Turn off the tester. Slightly move the sensor away from the device and lift the sensor tip. Detach the sensor completely from the tester so there is no connection between the two parts. Installing the Sensor: Ensure the tester is turned off. Check that the waterproof gasket is clean and intact. Attach the sensor to the tester by inserting hook “A” on the back of the device into hole “a” on the sensor tip. Ensure that the waterproof gasket is not twisted. Important: After replacing the sensor, follow the instructions in the user manual of the respective tester to make the device ready for accurate measurement. (These manuals are available with the products. Calibration and, if necessary, conditioning are usually required.) How can I check if my sensor shows signs of wear? Check the sensor condition as follows: Perform a 2-point calibration. If an error occurs during calibration, this indicates that the sensor has deteriorated. In this case, it is recommended to replace the sensor. Regular checks and timely replacement of sensors are essential to ensure the high standards and reliability of water quality measurements performed with HORIBA LAQUAtwin Pocket Testers. Manufacturer Part Nr. 3200934450
The HORIBA LAQUAtwin Pocket Tester series allows water quality parameters to be measured quickly and accurately directly on site. To ensure that these measurements are reliable and accurate, it is essential to check the sensors regularly and replace them with replacement sensors where necessary. These replacement sensors have been specifically developed for the HORIBA LAQUAtwin series and offer a wide range of variants for various measurements: pH, conductivity, salinity, redox (ORP), as well as ion-selective sensors for sodium, potassium, nitrate, calcium and fluoride. Each of these sensors has been developed with the aim of maximising the user-friendliness and accuracy for which HORIBA is renowned worldwide in the field of water quality testing. The advantages of HORIBA replacement sensors are: Easy replacement: The sensors are easy to replace, allowing measurements to resume quickly. Highest accuracy: The replacement sensors ensure that measurement results are precise and reliable. Wide range of measurements: Various types of sensors are available for different water quality parameters. Durability: The sensors are designed to have a long service life, even under challenging conditions. Instructions for sensor replacement: To ensure that your HORIBA LAQUAtwin Pocket Tester remains durable and accurate, please follow these steps when replacing the sensor: Removing the sensor Switch off the meter. Lift the tip of the sensor. Then slide the sensor slightly away from the meter. Remove the sensor completely from the meter (by pulling). Fitting the sensor Switch off the meter. Ensure that the water-resistant seal is clean and undamaged. Press the sensor onto the meter so that the hook ‘A’ on the back of the meter fits into the hole ‘a’ on the sensor tab. Make sure that the waterproof seal is not twisted. Important: To get the measuring device back up and running for accurate measurements, follow the steps in the user manual for the relevant tester after replacing the sensor. (Our products include such manuals. In most cases, calibration and, if necessary, conditioning are required.) Question: How can I check if my sensor is worn out? Answer: By checking the condition of the sensor as follows: To check the sensor condition, perform a 2-point calibration. If a calibration error occurs, this suggests that the sensor is deteriorating. The sensor should therefore be replaced. By carrying out regular checks and replacing sensors in good time, you can ensure the high quality and reliability of your water quality measurements using the HORIBA LAQUAtwin Pocket Testers. Important note on compatibility Please note: The Horiba LAQUAtwin conductivity, TDS and temperature multi-parameter testers, both old and new, are not compatible with one another. Similarly, the conditioning solutions for the old and new versions are not compatible with the respective device variants. How can you tell whether you have an older or a newer device? If your pocket tester is marked ‘4-cell’, you have the latest version of this device. In this case, you will need the replacement sensors listed in the cross-selling section, as well as the standard and conditioning solutions. These have been specially optimised for the new pocket testers and are not suitable for the older models. Manufacturer’s item number: 3200459672
The HORIBA LAQUAtwin Pocket Testers provide a comprehensive solution for immediate and precise measurement of water quality parameters directly in the field. To ensure that these measurements remain reliable and accurate, it is important to regularly check the sensors and replace them with spare sensors if necessary. The replacement sensors developed for the HORIBA LAQUAtwin series cover various types for different measurements: pH, conductivity, salinity, redox (ORP), as well as ion-selective sensors for sodium, potassium, nitrate, calcium, and fluoride. All of these sensors are designed to maximize user-friendliness and precision, qualities for which HORIBA is globally recognized in water quality testing. HORIBA replacement sensors ensure that users’ devices consistently deliver optimal performance and accurate measurements. Advantages of HORIBA Replacement Sensors Easy Replacement: Sensors can be quickly exchanged, allowing measurements to continue without delay. High Precision: Replacement sensors ensure that results are exact and reliable. Wide Measurement Range: Various sensor types are available to capture a broad spectrum of water quality parameters. Durability: Sensors are designed for long service life, even under challenging conditions. Sensor Replacement Instructions To ensure the longevity and accuracy of your HORIBA LAQUAtwin Pocket Tester, please follow these instructions when replacing a sensor: Removing the Sensor Turn off the tester. Carefully detach the sensor from the device and lift the sensor tip. Completely separate the sensor from the tester so that the two components are no longer connected. Installing the Sensor Ensure the tester is turned off. Check that the waterproof gasket is clean and undamaged. Attach the sensor to the tester by inserting hook “A” on the back of the device into hole “a” on the sensor tip. Make sure the waterproof gasket is not twisted. Important: After replacing the sensor, it is essential to follow the steps in the user manual of the respective tester to make the device ready for accurate measurements. (These manuals are available with the products. Calibration and, if necessary, conditioning are usually required.) How can I check if my sensor shows signs of wear? Check the sensor condition as follows: Perform a 2-point calibration. If an error occurs during calibration, this indicates that the sensor has deteriorated. In this case, replacing the sensor is recommended. Regular checks and timely replacement of sensors are essential to ensure the high standards and reliability of water quality measurements performed with HORIBA LAQUAtwin Pocket Testers. Please note: The salt exchange sensors, both old and new, are not compatible with one another. Similarly, the conditioning solutions for the old and new versions are not compatible with the respective device variants. How can you tell whether you have an older or a newer device? If your Pocket Tester is marked ‘4-cell’, you have the latest version of this device. In this case, you will need the replacement sensors listed in the cross-selling section, as well as the standard and conditioning solutions. These have been specially optimised for the new Pocket Testers and are not suitable for the older models. Manufacturer Part Nr. 3200597237
The HORIBA LAQUAtwin Pocket Tester series provides a comprehensive solution for immediate and precise measurement of water quality parameters directly in the field. To ensure these measurements remain reliable and accurate, it is essential to regularly check the sensors and, if necessary, replace them with spare sensors. The replacement sensors, specifically designed for the HORIBA LAQUAtwin series, cover a wide range of types for various measurements: pH, conductivity, salinity, redox (ORP), as well as ion-selective sensors for sodium, potassium, nitrate, calcium, and fluoride. Each sensor is engineered to maximize user-friendliness and accuracy, for which HORIBA is globally recognized in water quality testing. HORIBA replacement sensors ensure that users’ devices consistently deliver optimal performance and precise measurements. Advantages of HORIBA Replacement Sensors: Easy Replacement: Sensors can be quickly replaced, allowing measurements to continue without delay. High Accuracy: Replacement sensors ensure that results are exact and reliable. Comprehensive Measurement Range: Various sensor types are available to cover a wide range of water quality parameters. Durability: Sensors are designed for long service life under challenging conditions. Sensor Replacement Instructions: Follow these steps when replacing the sensor to maintain the longevity and accuracy of your HORIBA LAQUAtwin Pocket Tester: Removing the Sensor: Turn off the tester. Move the sensor slightly away from the device and lift the sensor tip. Detach the sensor completely from the tester. Installing the Sensor: Ensure the tester is turned off. Make sure the waterproof gasket is clean and intact. Mount the sensor onto the tester so that hook “A” on the back of the device fits into hole “a” on the sensor tip. Ensure the waterproof gasket is not twisted. Important: After replacing the sensor, follow the steps in the user manual of the respective tester to make the device ready for accurate measurement. (These manuals are available with the products. Calibration and, if necessary, conditioning are usually required.) How can I check if my sensor shows signs of wear? Check the sensor condition as follows: Perform a 2-point calibration. If an error occurs during calibration, this indicates that the sensor has deteriorated. In this case, it is advisable to replace the sensor. Regular checks and timely sensor replacement ensure that water quality measurements performed with the HORIBA LAQUAtwin Pocket Testers remain highly accurate and reliable. Manufacturer Part Nr. 3200997083
LAQUAtwin SALT-11: The world’s first pocket-sized salinity meter. Your mobile laboratory – for on-site use: Ideal for water quality testing in aquariums, foodstuffs and many other applications. HORIBAs unique compact meter integrates the electrode, display and sample vessel to enable simple, effective on-site testing via direct measurement with a single drop. Minimum sample volume: 0.12 ml Display of salinity and temperature Up to 2 calibration points Automatic calibration Automatic standard recognition: 0.50 & 5.00 % NaCl Automatic temperature compensation: 2%/°C fixed Temperature calibration: 5 to 40.0 °C 2 salinity curves: NaCl & seawater Automatic stable / hold measurement Automatic switch-off: 30 mins Low battery indicator IP67 rated dust and waterproof Replaceable sensor 400-hour battery life: continuous operation without backlight Material: ABS-epoxy housing and titanium coating with platinum-black sensor Display: custom (monochrome) digital LCD with backlight Operating conditions: 5 to 40°C, 85% or less relative humidity Warranty: 2 years – meter, 6 months – sensor Packaged in a handy carrying case Manufacturer’s item number: 3999960128 Supplied with 0.5% and 5.0% NaCl standards (14 ml each), conditioning solution (4 ml), 2 x CR2032 batteries, pipette, instructions and quick guide Additional information We would like to inform you of an upcoming product update for the LAQUAtwin pocket analysers. To enhance product safety and prevent infants and young children from accidentally swallowing the batteries, HORIBA will be introducing a new battery cover on all LAQUAtwin pocket-sized analysers. Overview of the product change Change: Battery cover for enhanced safety. Reason: To prevent accidental swallowing of batteries. Production date: from January 2026 in Japan Deliveries to EMEA distribution partners: from March 2026 As this change is currently being rolled out, mixed deliveries of the current and updated versions may occur during the transition phase. Please note: The salt exchange sensors, both old and new, are not compatible with each other. Similarly, the conditioning solutions for the old and new versions are not compatible with the respective device variants. How can you tell if you have an older or a new device? If your Pocket Tester is marked ‘4-cell’, you have the latest version of this device. In this case, you will need the replacement sensors listed in the cross-selling section, as well as the standard and conditioning solutions. These have been specially optimised for the new Pocket Testers and are not suitable for older models.
LAQUAtwin SALT-22: The world’s first pocket-sized salinity meter. Your mobile laboratory – for on-site use: Ideal for water quality testing in aquariums, foodstuffs and many other applications. HORIBAs unique compact meter integrates the electrode, display and sample chamber to enable simple, effective on-site testing through direct measurement with a single drop. Minimum sample volume: 0.3 ml (0.05 ml with sample sheet B) Display of salinity, mV and temperature Up to 2 calibration points Automatic calibration Automatic standard recognition: 0.5 & 5.0% NaCl (standard) Adjustable high and low calibration values Temperature calibration: 5 to 40.0 ºC Automatic stabilisation / automatic hold measurement Automatic switch-off: 30 mins Low battery indicator IP67 rated dust and waterproof Replaceable sensor 400-hour battery life: continuous operation without backlight Material: ABS-epoxy Display: custom (monochrome) digital LCD with backlight Operating conditions: 5 to 40 ºC, 85% or less relative humidity Warranty: 2 years – meter; 6 months – sensor Packaged in a handy carrying case Manufacturer’s item number: 3200689158 Supplied with 0.5% and 5.0% NaCl standards (14 ml each), 5 x Sample Form B, 2 x CR2032 batteries, pipette, instructions and quick guide Additional information We would like to inform you of an upcoming product update for the LAQUAtwin pocket meters. To enhance product safety and prevent infants and young children from accidentally swallowing the batteries, HORIBA will be introducing a new battery cover on all LAQUAtwin pocket-sized analysers. Overview of the product change Change: Battery cover for enhanced safety. Reason: To prevent accidental swallowing of batteries. Production date: from January 2026 in Japan Deliveries to EMEA distribution partners: from March 2026 As this change is currently being rolled out, mixed deliveries of the current and updated versions may occur during the transition phase. Please note: The salt exchange sensors, both old and new, are not compatible with each other. Similarly, the conditioning solutions for the old and new versions are not compatible with the respective device variants. How can you tell if you have an older or a new device? If your Pocket Tester is marked ‘4-cell’, you have the latest version of this device. In this case, you will need the replacement sensors listed in the cross-selling section, as well as the standard and conditioning solutions. These have been specially optimised for the new Pocket Testers and are not suitable for older models.
Mobile Sodium Ion Tester from Horiba with Temperature Measurement – precise and robust High-precision sodium ion tester with 2-point calibration – ideal for water and environmental analysis The Horiba LAQUAtwin Na-11 sodium ion tester was specifically designed for accurate measurement of sodium concentrations in a wide range of samples. The device enables direct on-site measurements. Its clear display shows both the Na⁺ concentration and the sample temperature in a single step, making field, laboratory, and greenhouse work significantly more efficient. Mobile sodium ion tester for precise on-site measurements Featuring 2-point calibration and automatic standard recognition (150 and 2000 ppm), the instrument can be easily adapted to different measurement requirements. The integrated temperature display and automatic temperature compensation ensure accurate results even under fluctuating environmental conditions. The robust IP67 housing is dustproof and waterproof, making the tester suitable for demanding daily use. With a battery life of approximately 400 hours, reliable long-term operation is ensured. The tester is supplied with standard solutions, sampling sheets, batteries, and matching pipettes for immediate use. Why sodium measurement matters – and why a handheld tester is the ideal solution Measuring sodium ions plays a crucial role in water, environmental, food, and agricultural analysis. Excessively high or low sodium concentrations can significantly affect water quality, soil structure, plant growth, and the quality of food products and drinking water. Regulatory limits and quality standards further require regular monitoring. A mobile sodium ion handheld tester enables fast and precise analysis directly at the point of use, without time-consuming sampling or laboratory analysis. The Horiba LAQUAtwin Na-11 combines this flexibility with high measurement accuracy and ease of use, making it ideal for routine monitoring, quality control, and research applications. Typical applications for the Horiba sodium ion tester Environmental monitoring: Measurement of sodium concentrations in surface and groundwater to assess water quality and ensure compliance with environmental standards. Food and beverage production: Testing sodium levels in food and beverages for quality assurance, product development, and regulatory compliance. Agriculture: Monitoring sodium content in irrigation water and soils to support plant health and optimize water management. Research & development: Use in laboratories for experimental studies on sodium ion behavior under varying conditions. Education: Utilized in schools and universities to demonstrate the use of ion-selective electrodes in analytical chemistry. Additional information We would like to inform you of an upcoming product update for the LAQUAtwin handheld analysers. To enhance product safety and prevent infants and young children from accidentally swallowing the batteries, HORIBA will be introducing a new battery cover on all LAQUAtwin pocket-sized analysers. Overview of the product change Change: Battery cover for enhanced safety. Reason: To prevent accidental swallowing of batteries. Production date: From January 2026 in Japan Deliveries to EMEA distribution partners: From March 2026 As this change is currently being rolled out, mixed deliveries of the current and updated versions may occur during the transition period. Frequently asked questions How long is the warranty period for HORIBA pocket testers? The warranty period is two years from delivery for commercial customers. How many measurements can be taken before the sensor needs to be replaced? This varies depending on the application, use and storage of the Horiba tester. As a rule, the sensor should be replaced after one year. How long is the warranty period for replacement sensors for pocket testers? The warranty period is 12 months after delivery for commercial customers. How do you clean the pocket tester? The pocket tester can be rinsed under water. We recommend cleaning with DI water (deionised). Tissue paper is recommended for drying after cleaning. How can the pocket tester be reset to factory settings? (e.g. in the event of an incorrect measurement result) This information can be found in the operating instructions. These can be found in the download area of the shop and on the product. Is calibration necessary before each measurement? Basically, yes. Further information can be found in the operating instructions.
HORIBA Ion standard solutions, ionic strength controllers and ion-selective electrode filling solutions are indispensable for accurate and reproducible measurements with ion-selective electrodes (ISE). A large number of analyses in laboratories and in the field, such as testing water and wastewater quality, environmental monitoring and quality control in industrial processes, rely on these solutions. Ionic standard solutions are used to calibrate ion-selective electrodes and ensure precise measurement. Horiba's standard solutions have a known ion concentration. They are therefore essential for setting up the electrodes correctly before using them for test runs. Ionic strength controllers are specifically designed to adjust the ionic strength of the sample to enable accurate measurements. They are particularly important when the composition of the samples could affect the measurement or in samples with low ionic strength. The ionic strength can be adjusted to stabilize the ionic activity in the solution. This leads to more accurate measurement results. Ion-selective electrode filling solutionsIon-selective electrode filling solutions are specific solutions that are filled into ion-selective electrodes. They ensure the proper operation of the electrode and help to maintain the potential required to measure the specific ion. To ensure that measurements meet international standards and to ensure conformity with regulatory and compliance standards, these specialized solutions are essential. Many industries, from pharmaceutical to environmental, use these solutions to meet their quality and safety requirements. For users working in areas such as water analysis, environmental monitoring or regulatory testing environments, these solutions ensure the accuracy and reliability required for critical measurements. To provide reliable data for important environmental, health and safety decisions, they are a crucial part of analytical chemistry. Overall, HORIBA's solutions enable experts to make the best use of their instruments and achieve the precise results required for their applications. Manufacturer article number: 3200697181 (500-NO3-IFS)
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3999960108
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Article Number: 3200691954
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3999960109
HORIBA Ion standard solutions, ionic strength controllers and ion-selective electrode filling solutions are indispensable for accurate and reproducible measurements with ion-selective electrodes (ISE). A large number of analyses in laboratories and in the field, such as testing water and wastewater quality, environmental monitoring and quality control in industrial processes, rely on these solutions. Ionic standard solutions are used to calibrate ion-selective electrodes and ensure precise measurement. Horiba's standard solutions have a known ion concentration. They are therefore essential for setting up the electrodes correctly before using them for test runs. Ionic strength controllers are specifically designed to adjust the ionic strength of the sample to enable accurate measurements. They are particularly important when the composition of the samples could affect the measurement or in samples with low ionic strength. The ionic strength can be adjusted to stabilize the ionic activity in the solution. This leads to more accurate measurement results. Ion-selective electrode filling solutionsIon-selective electrode filling solutions are specific solutions that are filled into ion-selective electrodes. They ensure the proper operation of the electrode and help to maintain the potential required to measure the specific ion. To ensure that measurements meet international standards and to ensure conformity with regulatory and compliance standards, these specialized solutions are essential. Many industries, from pharmaceutical to environmental, use these solutions to meet their quality and safety requirements. For users working in areas such as water analysis, environmental monitoring or regulatory testing environments, these solutions ensure the accuracy and reliability required for critical measurements. To provide reliable data for important environmental, health and safety decisions, they are a crucial part of analytical chemistry. Overall, HORIBA's solutions enable experts to make the best use of their instruments and achieve the precise results required for their applications. Manufacturer article number: 3200697185 (500-K-IFS)
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200997084
Wash bottle for LAQUAtwin 4M setManufacturer article number: 3200774604
Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.
Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.
Box of 25x20ml sachets Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.
Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.
Der Milwaukee C65 Waterproof EC Pen bringt robuste Technik für präzise Leitfähigkeitsmessungen im niedrigen Bereich. Automatische Temperaturkompensation (ATC) sorgt für verlässliche Messergebnisse bei wechselnden Bedingungen. Dank wasserdichtem Gehäuse und austauschbarer Sonde ist das Gerät ideal für den Outdoor-Einsatz, Labor oder Messungen in feuchten Umgebungen.
Der Milwaukee C66 Waterproof EC Pen überzeugt durch Robustheit und hohe Messbereiche. Mit ATC und Austauschsonde liefert er auch bei extremen Bedingungen präzise Leitfähigkeitswerte. Ideales Werkzeug für Aquaristik, Industrie oder Feldarbeit – langlebig, zuverlässig und leicht zu bedienen.
Including:230ml bottle MA9007 pH 7.01 calibration buffer solution230ml bottle MA9061 1413 µS/cm conductivity calibration solution230ml bottle MA9015 storage solution230ml bottle MA9016 cleaning solution
Including:230ml bottle MA9004 pH 4.01 Calibration Buffer Solution230ml bottle MA9007 pH 7.01 Calibration Buffer Solution230ml bottle MA9015 Storage Solution230ml bottle MA9016 Cleaning Solution Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.
Milwaukee CD600 TDS-Tester – misst zuverlässig die Konzentration gelöster Feststoffe (TDS). Kristallklare Anzeigen, einfache Handhabung. Zuverlässig für Wasserqualitätskontrolle, Umweltanalyse & Hydroponik. Kompakt, präzise, praxistauglich.
Milwaukee CD601 EC-Pen – handliches Leitfähigkeitstool für schnelle & verlässliche Messungen. Messbereich 0–1990 µS/cm, Auflösung 10 µS/cm, mit ATC (Automatische Temperaturkompensation); Genauigkeit ±2 % FS. Einfache 1-Punkt-Kalibrierung, robust, ideal für Aquarien, Wasseranalysen & Feldmessungssituationen.