In our online shop we offer you a broad product portfolio of various pocket testers. You can select the right pocket tester for you according to various criteria: measurement parameters, application area, quality features or manufacturer.
With the uncomplicated to handle portable analyzers, the measurement of viscous liquids, solids and even powder samples is possible. Only a few drops of the standard solution or sample on the highly sensitive sensor are required to obtain fast and reliable test results. This procedure saves you time and, in addition to industrial use, also allows the handheld meters to be used in the home.
At the same time, the integrated analysis function, the large illuminated display and the replaceable batteries make the handheld analyzer from Horiba very user-friendly.
Our instruments are used, among others, in:
- Water or liquid analysis
- Conformity testing
- Food or environmental analysis
- Quality control
- Biotechnology
Choose your pocket tester from the different brands:
- Horiba
- Milwaukee
- XS Instruments
Filter products
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200457723
Explore HORIBA's premium profile solutions for pH, ORP and conductivity measurements, specifically designed for handheld and laboratory meters. Our solutions are designed to meet the needs of different users and ensure that your measurements are accurate. Here are a few of our products that provide a clear overview and easy selection: - pH standard solutions are available in different pH value classes: e.g. 4.01, 7.00, 10.01. These solutions are indispensable for the calibration of pH electrodes and have a high degree of accuracy. - Redox standard solutions (ORP): These solutions offer values from 200 mV to 650 mV, enabling precise adjustment of redox electrodes. Standard solutions for conductivity: These are used to calibrate conductivity sensors and are available in different conductivity ranges. - Internal filling solutions: These solutions are specially designed for pH and reference electrodes and ensure optimum functionality as well as a long service life for your electrodes. Users:- Our NIST-traceable hygienic bottle solutions are ideal for environmental laboratories using pH and ORP buffer solutions to monitor water quality in natural waters. They enable safe and accurate calibration without the risk of contamination. - Our buffer solutions provide a reliable basis for compliant results in the pharmaceutical industry, where accurate pH measurements are critical for drug formulation and quality control. - Our pH and redox solutions are of great importance to the food and beverage industry and play a crucial role in the quality of products, from wine production to milk processing. - Our solutions are used by research institutions and universities to conduct their scientific experiments and train the next generation of scientists. - Our conductivity standard solutions are used by water treatment plants to improve their purification and filtration processes. Manufacturer information: Because HORIBA is synonymous with quality and precision, you can trust our professional solutions to complement your measurement equipment and extend its life. HORIBA's innovative hygienic bottles differ significantly from conventional bottles as they allow contamination-free removal by simply squeezing. As the lower part of the bottle always remains fresh and untouched, it is particularly advantageous for applications where cleanliness and accuracy are crucial. Use HORIBA solutions to ensure the accuracy of your measurements and promote the functionality of your measuring devices. HORIBA high quality conductivity calibration solution to calibrate your electrodes The 250 ml, 500 ml and 1000 ml bottle is characterized by a special hygienic closure, which protects the conductivity calibration solution from contamination. To provide the required calibration solution, simply squeeze the bottle together and enough conductivity calibration solution is delivered to the upper part of the bottle to perform a calibration.
Calcium (Ca2+) ion-selective electrode for 300 seriesThe new electrode is suitable for the LAQUA WQ-300 series from Horiba and offers precise and reliable measurements for ions in aqueous solutions. It is characterised by its user-friendly handling and environmentally friendly design and can be used for a wide range of applications.Linearity in measurement range:The range where the calibration curve has linearity is called the measurement range. When lower concentration is measured where the linearity is not established, perform calibration at two points in the lower concentration range.Below graph shows the theoretical calibration curve of a calcium ion selective electrode.Influence of pH:The impact of the pH may cause a decrease in the slope of the ion selective electrode, or parallel shifting of the calibration curve. To prevent these effects, set the pH to an appropriate value in advance and keep it constant.Interfering ions:Ion selective electrodes have good selectivity with respect to the ions to be measured, but they may react to the other ions. When using the ion electrode method, it is important to know the effects of coexistent ions and take measures to avoid them. Interfering ions may form compounds with poor solubility or may form complex salts with the structure material of the ion selective membrane, these may to have a significant impact on the measured value.Conditioning:An electrode is conditioned by soaking it in a standard solution for 1 hour or longer. Use a standard solution whose concentration is 100 mg/L or more.In the following cases, perform conditioning of the electrode before calibration.• Before the first use.• Before use after storage for 2 weeks or longer.• If the electrode is less responsive.Calibration:Always calibrate with at least 2 calibration solutions which are 1 decade apart and bracket the expected measurement value.Use fresh calibration solutions and do not re-use them.• Below 10 ppm (mg/L)First solution between 1 and 10ppmSecond solution between 10 and 50 ppm• Between 10 and 100 ppm (mg/L)First solution between 10 and 100ppmSecond solution between 100 and 1000 ppm• Above 100 ppm (mg/L)First solution between 100 and 1000ppmFurther information can be found in the download area of the store. Manufacturer article number: 3200986786 (300-CA-C)
Potassium (K+) ion-selective electrode for 300 series The new electrode is suitable for the LAQUA WQ-300 series from Horiba and offers precise and reliable measurements for ions in aqueous solutions. It is characterised by its user-friendly handling and environmentally friendly design and can be used for a wide range of applications.Features:Measurement parameters: Potassium (K+) Solid-state electrodes that do not require refilling Double junction made of porous sintered polyethylene Integrated temperature sensor Environmentally friendly design made from bio-based plastic Supplied with calibration and ionic strength adjustment solutions Robust housing made of polycarbonate and PVC Low maintenance, simply rinse and seal Waterproof according to IP67Linearity in measurement range:The range where the calibration curve has linearity is called the measurement range. When lower concentration is measured where the linearity is not established, perform calibration at two points in the lower concentration range.Influence of pH:The impact of the pH may cause a decrease in the slope of the ion selective electrode, or parallel shifting of the calibration curve. To prevent these effects, set the pH to an appropriate value in advance and keep it constant.→Set the pH to an appropriate value in advance and keep it constant.If the pH of the sample solution exceeds 11, adjust the pH in the range of 5 to 11 by adding hydrochloric acid HCl.If the pH of the sample solution is less than 5, adjust the pH in the range of 5 to 11 by adding sodium hydroxide NaOH.Interfering ions:Ion selective electrodes have good selectivity with respect to the ions to be measured, but they may react to the other ions. When using the ion electrode method, it is important to know the effects of coexistent ions and take measures to avoid them. Interfering ions may form compounds with poor solubility or may form complex salts with the structure material of the ion selective membrane, these may to have a significant impact on the measured value. Conditioning:An electrode is conditioned by soaking it in a standard solution for 1 hour or longer. Use a standard solution whose concentration is 100 mg/L or more.In the following cases, perform conditioning of the electrode before calibration.• Before the first use.• Before use after storage for 2 weeks or longer.• If the electrode is less responsive.Calibration:Always calibrate with at least 2 calibration solutions which are 1 decade apart and bracket the expected measurement value.Use fresh calibration solutions and do not re-use them.• Below 10 ppm (mg/L)First solution between 1 and 10ppmSecond solution between 10 and 50 ppm• Between 10 and 100 ppm (mg/L)First solution between 10 and 100ppmSecond solution between 100 and 1000 ppm• Above 100 ppm (mg/L)First solution between 100 and 1000ppmSecond solution above 1000 ppmFurther information can be found in the data sheets in the download area of the store. Manufacturer article number: 3200986785 (300-K-C)
Sodium (Na+) ion-selective electrode for 300 seriesThe new electrode is suitable for the LAQUA WQ-300 series from Horiba and offers precise and reliable measurements for ions in aqueous solutions. It is characterized by its user-friendly handling and environmentally friendly design and is versatile in use. Features:Measurement parameters: Sodium (Na+)Solid-state electrodes that do not require refillingDouble junction made of porous sintered polyethyleneIntegrated temperature sensorEnvironmentally friendly design made from bio-based plasticDelivery includes calibration and ionic strength adjustment solutionsRobust housing made of polycarbonate and PVCLow maintenance, simply rinse and sealWaterproof according to IP67Linearity in measurement range:The range where the calibration curve has linearity is called the measurement range. When lower concentration is measured where the linearity is not established, perform calibration at two points in the lower concentration range.Influence of pH:The impact of the pH may cause a decrease in the slope of the ion selective electrode, or parallel shifting of the calibration curve. To prevent these effects, set the pH to an appropriate value in advance and keep it constant.→Set the pH to an appropriate value in advance and keep it constant.If the pH of the sample solution exceeds 10, adjust the pH in the range of 5 to 10 by adding hydrochloric acid HCl.If the pH of the sample solution is less than 5, adjust the pH in the range of 5 to 10 by adding sodium hydroxide NaOH.Interfering ions:Ion selective electrodes have good selectivity with respect to the ions to be measured, but they may react to the other ions. When using the ion electrode method, it is important to know the effects of coexistent ions and take measures to avoid them. Interfering ions may form compounds with poor solubility or may form complex salts with the structure material of the ion selective membrane, these may to have a significant impact on the measured value. Conditioning:An electrode is conditioned by soaking it in a standard solution for 1 hour or longer. Use a standard solution whose concentration is 100 mg/L or more.In the following cases, perform conditioning of the electrode before calibration.• Before the first use.• Before use after storage for 2 weeks or longer.• If the electrode is less responsive.Calibration:Always calibrate with at least 2 calibration solutions which are 1 decade apart and bracket the expected measurement value.Use fresh calibration solutions and do not re-use them.• Below 10 ppm (mg/L)First solution between 1 and 10ppmSecond solution between 10 and 50 ppm• Between 10 and 100 ppm (mg/L)First solution between 10 and 100ppmSecond solution between 100 and 1000 ppm• Above 100 ppm (mg/L)First solution between 100 and 1000ppmSecond solution above 1000 ppmFurther documentation can be found in the download area of our store Manufacturer article number: 3200986787 (300-NA-C)
Ammonium (NH4+) ion-selective electrode for 300 seriesThe new electrode is suitable for the LAQUA WQ-300 series from Horiba and offers precise and reliable measurements for ions in aqueous solutions. It is characterized by its user-friendly handling and environmentally friendly design and is versatile in useFeatures:Measurement parameters: Ammonium solid-state electrodes that do not require refillingDouble junction made of porous sintered polyethyleneIntegrated temperature sensorEnvironmentally friendly design made from bio-based plasticSupplied with calibration and ionic strength adjustment solutionsRobust housing made of polycarbonate and PVCLow maintenance, simply rinse and seal Waterproof according to IP67Linearity in the measuring range:The range in which the calibration curve shows linearity is called the measuring range. If a lower concentration is measured at which the linearity is not given, the calibration must be carried out at two points in the lower concentration range.Influence of the pH value:The ammonia electrode can be used in a pH range from 5 to 8. The influence of the pH value can cause a decrease in the slope of the ion-selective electrode or a parallel shift of the calibration curve. To avoid these effects, set the pH value to a suitable value in advance and keep it constant. Interfering ions:Ion-selective electrodes have good selectivity with respect to the ions being measured, but can react to other ions. When using the ion electrode method, it is important to be aware of the effects of coexisting ions and to take measures to avoid them. Interfering ions can form compounds with poor solubility or form complex salts with the structural material of the ion-selective membrane, which can significantly affect the measured value.Conditioning:An electrode is conditioned by immersing it in a standard solution for 1 hour or longer. Use a standard solution with a concentration of 100 mg/L or more. In the following cases, the electrode must be conditioned before calibration. Before first use. Before use after storage for 2 weeks or longer. When the electrode is less sensitive.Calibration:Always calibrate with at least 2 calibration solutions that are a decade apart and include the expected reading. Use fresh calibration solutions and do not reuse them.- Below 10 ppm (mg/L)First solution between 1 and 10 ppmSecond solution between 10 and 50 ppm- Between 10 and 100 ppm (mg/L)First solution between 10 and 100 ppmSecond solution between 100 and 1000 ppm- Over 100 ppm (mg/L)First solution between 100 and 1000 ppmSecond solution above 1000 ppmFurther information can be found in the download area of the store. Manufacturer article number: 3200986783 (300-NH4-C)
Nitrate (NO3-) ion selective electrode for 300 seriesThe new electrode is suitable for the LAQUA WQ-300 series from Horiba and offers precise and reliable measurements for ions in aqueous solutions. It is characterised by its user-friendly handling and environmentally friendly design and can be used for a wide range of applications.Features:Measurement parameters: Nitrate (NO3-) Solid-state electrodes that do not require refillingDouble junction made of porous sintered polyethyleneIntegrated temperature sensor Environmentally friendly design made from bio-based plasticSupplied with calibration and ionic strength adjustment solutionsRobust housing made of polycarbonate and PVCLow maintenance, simply rinse and sealWaterproof according to IP67Linearity in measurement range:The range where the calibration curve has linearity is called the measurement range. When lower concentration is measured where the linearity is not established, perform calibration at two points in the lower concentration range.Influence of pH:The impact of the pH may cause a decrease in the slope of the ion selective electrode, or parallel shifting of the calibration curve. To prevent these effects, set the pH to an appropriate value in advance and keep it constant.Interfering ions:Ion selective electrodes have good selectivity with respect to the ions to be measured, but they may react to the other ions. When using the ion electrode method, it is important to know the effects of coexistent ions and take measures to avoid them. Interfering ions may form compounds with poor solubility or may form complex salts with the structure material of the ion selective membrane, these may to have a significant impact on the measured value.Conditioning:An electrode is conditioned by soaking it in a standard solution for 1 hour or longer. Use a standard solution whose concentration is 100 mg/L or more.In the following cases, perform conditioning of the electrode before calibration.• Before the first use.• Before use after storage for 2 weeks or longer.• If the electrode is less responsive.Calibration:Always calibrate with at least 2 calibration solutions which are 1 decade apart and bracket the expected measurement value.Use fresh calibration solutions and do not re-use them.• Below 10 ppm (mg/L)First solution between 1 and 10ppmSecond solution between 10 and 50 ppm• Between 10 and 100 ppm (mg/L)First solution between 10 and 100ppmSecond solution between 100 and 1000 ppm• Above 100 ppm (mg/L)First solution between 100 and 1000ppmSecond solution above 1000 ppmFurther information can be found in the data sheets in the download area of the store Manufacturer article number: 3200986784 (300-NO3-C)
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200053514
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200053535
Manufacturer's number: 3014081712For water with low conductivity (e.g. deionized, distilled)Glass housing, platinum/platinum black, k=1, conductivity measuring cell with integrated temperature sensor Waterproof
Manufacturer's number: 3014081714For water with high conductivity Glass body, platinum/platinum black, k=10, conductivity measuring cell with integrated temperature sensor Waterproof
Manufacturer number: 3014082592For column chromatography with a very small sample quantityGlass body, platinum/platinum black, k=10, conductivity measuring cell
Mobile Analysis Laboratory for Ion Measurements – Versatile Use Compact kit for simultaneous determination of multiple water and environmental parameters The Horiba 4M LAQUAtwin Kit is a mobile laboratory that allows you to determine important ion parameters directly on-site. The case contains pocket testers for measuring sodium, potassium, nitrate, and calcium, as well as for temperature measurement. Each device uses ion-selective electrodes for targeted analysis of small samples and provides fast, reliable results. In addition to the four measurement devices, the kit includes calibration solutions and a wash/spray bottle for sensor cleaning. The sensors can be stored dry without special storage solutions. Compact Multi-Parameter Kit for Flexible On-Site Analyses The set is designed for measurement tasks where multiple ions need to be detected simultaneously, for example when monitoring drinking and process water, performing environmental checks of water bodies, conducting aquaculture analyses, or agricultural research. Thanks to the case, all essential testers including accessories are always on hand and ready for immediate use. The measurement results are available in a short time and are reliable and reproducible – ideal for routine and control measurements in the field. All components are neatly arranged in the case and ready for use at any time. An additional advantage is that the sensors can be stored dry without special storage solutions. Due to its compact design, the kit is particularly suitable for mobile applications where multiple ion parameters need to be determined quickly one after the other or in parallel. Why Multi-Parameter Ion Measurements Are Useful – and a Mobile Kit Is Ideal In many applications, not just a single measurement is important, but the interaction of multiple ion parameters. Sodium, potassium, nitrate, and calcium together influence water quality, biological processes, plant growth, and technical operations. Single measurements in a laboratory are often time-consuming and inflexible. A mobile analysis kit allows simultaneous detection of multiple parameters directly on-site. This allows relationships to be recognized more quickly, decisions to be made more reliably, and measurement campaigns to be carried out more efficiently. The Horiba 4M LAQUAtwin Kit combines these advantages in a compact, user-friendly system.
Manufacturer's number.: 3200698386Ion selective electrodes respond to the concentration of specific ions in the test liquid and are variable potential electrodes. They are used in combination with reference electrodes to measure the concentration of certain ions.When measuring with an ion meter, the ion concentration can be read directly by calibrating with different standard solutions. Since the volume reading changes with temperature, the measurements must be taken at a fixed temperature.
Manufacturer number: 3014081107This refillable pH electrode can measure samples in very slender test tubes (e.g., NMR test tubes) due to its long, thin, glass-body.Waterproof
Manufacturer number: 3014080850This glass electrode with conical tip and integrated temperature sensor is designed for pH measurement in food.
Manufacturer number: 3014079136This glass-body, refillable pH electrode with temperature sensor has a sleeve junction for improved stability and repeatability. Ideal for highly accurate pH measurement.
Manufacturer's number: 3200697407 Ion-selective electrodes respond to the concentration of specific ions in the test fluid and are variable potential electrodes. They are used in combination with reference electrodes to measure the concentration of certain ions. When measuring with an ion meter, the ion concentration can be read directly by calibrating with different standard solutions. Since the volume reading changes with temperature, measurements must be taken at a fixed temperature. Note: Chloride sensor, if selected, is supplied without chloride ion strength regulator and chloride electrode filling solution. This must be procured by the customer. Without the filling solution the sensor can´t be used.
Manufacturer's number: 3200693774 Ion-selective electrodes respond to the concentration of specific ions in the test fluid and are variable potential electrodes. They are used in combination with reference electrodes to measure the concentration of certain ions. When measuring with an ion meter, the ion concentration can be read directly by calibrating with different standard solutions. Since the volume reading changes with temperature, the measurements must be taken at a fixed temperature.
Manufacturer's number: 3200697408 Ion-selective electrodes respond to the concentration of specific ions in the test fluid and are variable potential electrodes. They are used in combination with reference electrodes to measure the concentration of certain ions. When measuring with an ion meter, the ion concentration can be read directly by calibrating with different standard solutions. Since the volume reading changes with temperature, the measurements must be taken at a fixed temperature.
Manufacturer's Number: 3200697409 Ion-selective electrodes respond to the concentration of specific ions in the test fluid and are variable potential electrodes. They are used in combination with reference electrodes to measure the concentration of certain ions. When measuring with an ion meter, the ion concentration can be read directly by calibrating with different standard solutions. Since the volume reading changes with temperature, measurements must be taken at a fixed temperature.
Manufacturer's number: 3200697410 Ion-selective electrodes respond to the concentration of specific ions in the test fluid and are variable potential electrodes. They are used in conjunction with reference electrodes to measure the concentration of certain ions. When measuring with an ion meter, the ion concentration can be read directly by calibrating with different standard solutions. Since the volume reading changes with temperature, measurements must be taken at a fixed temperature.
Manufacturer's number: 3200697411Chloride (Cl-) replacement electrode tip for 6560S-10C
Manufacturer's number: 3200693606Fluoride (Fl-) replacement electrode tip for 6561S-10C