Milwaukee MW105 MAX Waterproof pH / ORP / Temp Portable Meter

Article number: 895557
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "Milwaukee MW105 MAX Waterproof pH / ORP / Temp Portable Meter"

The MW105 MAX meter combines all the features of a benchtop meter in an IP67-rated portable meter.
The units are equipped with a range of new diagnostic functions that improve the reliability of pH measurement:

  • Waterproof IP67 housing
  • Extended pH range: -2.00 to 20.00 pH
  • Up to 3-point automatic pH calibration, 7 standard calibration buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45)
  • alphanumeric LCD display for user-friendly, intuitive information, warning and error messages
  • automatic switch-off function to conserve battery power
  • internal clock and date for monitoring various time-dependent functions (calibration timestamp, calibration timeout)
  • Special GLP button

Dimensions

Height 11,5 cm
Length 30,5 cm
Width 28 cm

Weight

Weight 1,22 kg

Other attributes

Brand Milwaukee
Country of origin RO
Customs tariff number 38221900
Parameter Combined Multiparameter, ORP, Thermometers (°C), pH
Quality Advanced
Technical specifications
pH range*: -2.00 to 20.00 pH
pH range electrode: 0 to 12 pH 
ORP range: ±2000.0mV 
Temperature range meter: -20.0 to 120.00°C (-4.0 to 248.0°F) 
Temperature range electrode: -5 to 70°C (23 to 158°F)
Resolution: 0.01 pH
Resolution: 0.1mV 
Resolution: 0.1°C (0.1°F) 
Accuracy*: ±0.02 pH @ 25°C / 77°F 
Accuracy: ±1mV
Accuracy: ±0.5°C (±1°C outside) | ±1°F (±2°F outside) 
pH calibration: up to 3 points automatic pH calibration | 7 standard buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)  
ORP calibration: factory calibrated  
Temperature compensation*: Automatic, -20.0 to 120.0°C (-4.0 to 248.0°F) or manual (without temperature probe)
pH electrode: MA906BR/1 amplified pH/temperature probe (supplied)
Accuracy electrode: ±0.02 pH (range 0 to 12 pH)  
Temperature probe: Built-in temperature sensor 
Impedance: 10 Ohm 
Battery type: 3 X 1.5V akaline AA (supplied)
Battery life: Approx. 200 hours  
Operating time automatic switch-off: selectable 5, 10, 30, 60 min. or off 
Environment: 0 to 50°C / 32 to 122°F; max. RH 95%  
Dimensions: 200 x 85 x 50 mm (7.9 x 3.3 x 2.0 in.) 
Housing: IP67
Weight: .26 Kg / 0.58 lbs (with battery)  
Warranty: 2 years

*Limits are reduced to the sensor limits
Skip product gallery

Spare parts and accessories

Milwaukee MA906BR/1 Reinforced pH Redox Temp Replacement Electrode with Durable Epoxy Body
Milwaukee MA906BR/1 Reinforced pH/Redox/Temp. replacement electrode
Article number: 896140
Measuring range: 0 - 12 pH | 23 to 221°F (-5 to 70°C) | Measurement parameters: pH, Temperature

The Milwaukee MA906BR/1 Reinforced pH/Redox/Temp replacement electrode for Milwaukee MW105 pH/Temp and MW106 pH/ORP/Temp meters.The MA906BR/1 has a rugged housing (epoxy) and comes with a 1m cable and BNC connector (meters sold separately).OPR probes for MW105 or MW106 are available separately.The probe connects quickly and firmly to a BNC connector. No slipping off is to be feared.

€336.65*
Milwaukee M10004B pH 4.01 calibration solution, front of bag with product name and volume
Milwaukee M10004B pH 4.01 calibration solution in a sachet, 25 sachets á 20ml
Article number: 895526

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€82.59*
Milwaukee M10007B pH 7.01 calibration solution bag front, 25 bags of 20 ml visible, calibration solution pH 7.01 for accurate measurements
Milwaukee M10007B pH 7.01 calibration solution in a sachet, 25 sachets á 20ml
Article number: 895527

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€82.59*
Milwaukee M10010B pH 10.01 calibration solution bag front, 25 bags of 20 ml each, calibration solution pH 10.01 for precise pH measurement, Milwaukee pH 10 calibration solution in a practical bag, pH 10 reference solution for calibrating measuring devices
Milwaukee M10010B pH 10.01 calibration solution in a sachet, 25 sachets á 20ml
Article number: 895528

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€82.59*
Milwaukee pH 4.01 Calibration Buffer Solution 230ml (MA9004) Product number: 896151
Milwaukee pH 4.01 Calibration Buffer Solution 230ml (MA9004)
Article number: 896151
pH buffer: pH 4.01 (@25°C) |

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€55.22*
Milwaukee pH 6.86 Calibration Buffer Solution 230ml (MA9006) Product number: 896152
Milwaukee pH 6.86 Calibration Buffer Solution 230ml (MA9006)
Article number: 896152
pH buffer: pH 6.86 (@25°C) |

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€55.22*
Milwaukee pH 7.01 Calibration Buffer Solution 230ml (MA9007) Product number: 896153
Milwaukee pH 7.01 Calibration Buffer Solution 230ml (MA9007)
Article number: 896153
pH buffer: pH 7.01 (@25°C) |

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€51.65*
Milwaukee pH 9.18 Calibration Buffer Solution 230ml (MA9009) Product number: 896154
Milwaukee pH 9.18 Calibration Buffer Solution 230ml (MA9009)
Article number: 896154
pH buffer: pH 9.18 (@25°C) |

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€55.22*
Milwaukee pH 10.01 Calibration Buffer Solution 230ml (MA9010) Product number: 896155
Milwaukee pH 10.01 Calibration Buffer Solution 230ml (MA9010)
Article number: 896155
pH buffer: pH 10.01 (@25°C) |

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€55.22*
Milwaukee storage solution, 230ml (MA9015) Product number: 896165
Milwaukee storage solution, 230ml (MA9015)
Article number: 896165

for pH/ORP electrodes

€51.65*
Milwaukee Cleaning Solution, 230ml (MA9016) Product number: 896166
Milwaukee Cleaning Solution, 230ml (MA9016)
Article number: 896166

for pH/ORP electrodes

€55.22*
Milwaukee MA924B/1 Redox Electrode with Glass Body, Double Junction and Refillable Function
Milwaukee MA924B/1 Refillable Combination ORP Electrode
Article number: 896137

DESIGN FEATURESThe MA924B/1 offers the following design features:PLATINUM SENSING RINGThe platinum ring design is the preferred for most ORP applications.GLASS BODYGlass body is ideal use in wine applications as it is easily cleaned and gives fast results.DOUBLE JUNCTION REFERENCEThe double junction means that virtually no silver from the reference cell is mixed with the sample and reduces the risks of clogging.REFILLABLEThe ability to refill the electrolyte solution extends the life of the probe. Use MA9011 3.5M KCl fill solution. With a refillable ORP electrode, best results are achieved if the fill cap is removed to create a higher flow rate. This results in a faster and more stable reading.

€510.63*