Horiba LAQUAtwin Fluoride Ion (F-) tester with 2 calibration points and temperature measurement (F-11)

Product number: 895693

Product information "Horiba LAQUAtwin Fluoride Ion (F-) tester with 2 calibration points and temperature measurement (F-11)"

Manufacturer Part No. 3200934412

LAQUAtwin F-11: The world's first pocket-sized fluoride ion analyser

Your mobile laboratory - for on-site use

HORIBA's unique compact meter integrates electrode, display and sample container to enable simple, effective on-site testing by direct measurement with a single drop.

Revolutionary fluoride ion analysis: Be part of history with the world's first and only pocket-sized fluoride ion analyser.

Measurement capabilities for microsamples: The interchangeable sensor with a lanthanum trifluoride crystal enables measurements in samples as small as 0.3 ml (or 0.1 ml with a sampling sheet).

Comprehensive measurement range: With a measurement range of 0.1 to 990 ppm or mg/L, the meter provides accurate fluoride ion readings.

Unrivalled accuracy: With an accuracy of 2 % of the actual value, the meter ensures reliable results for your analyses.

Convenient two-point auto-calibration: Achieve accuracy with two-point calibration as the meter automatically recognises and calibrates the 1 ppm and 10 ppm fluoride ion standard solutions included in the kit. You can adjust the calibration with other standard solutions that differ in concentration by a factor of ten.

Multiplying compensation function: Taking into account the sample dilution in the measured value, the meter has a multiplying compensation function to calculate the correct concentration.

Auto Stable & Auto Hold measurement modes: To assist users in recording stable readings, the meter displays a smiley face and can freeze the reading.

Temperature Calibration: The meter displays temperatures up to 50.0°C and allows for temperature correction through its calibration function.

IP67 rating: Water and dustproof meter with digital LCD display and backlighting

Complete package for fluoride ion testing on the go: Each F-11 meter comes with 1ppm and 10ppm fluoride ion standard solutions (14ml each), TISAB solution (14ml), 5ml plastic cup, batteries, syringe and 5 sampling sheets.

Dimensions

Height 3,4 cm
Length 18,2 cm
Width 14,3 cm

Weight

Weight 300 g

Other attributes

Applications Water Treatment
Brand Horiba
Country of origin JP
Customs tariff number 9027890001
Parameter Fluoride Ion (F-)
Quality Advanced
Technical data
Measuring principle: Ion selective electrode 
Minimum sample volume: 0.3 ml (0.01 ml with sampling sheet B)

 

Measurement range:

0.1 to 990 ppm (mg/L)

 

Resolution:

0.1 to 9.9 ppm: 0.1 ppm
10 to 99 ppm: 1 ppm
100 to 990 ppm: 10 ppm
Accuracy: ± 2% of the current value
Maximum calibration points: 2
Temperature display / resolution: 0 to 50.0 °C / 0.1 °C

 

Functions

- Automatic standard detection
- Changeable low and high calibration values
- Temperature calibration
- Multiplying compensation (0.01 to 9.90)
- Auto-hold / auto-stable measurement modes
- Automatic switch-off (30 min.) 
- Low battery indicator 
- IP67 water and dust proof
- Replaceable sensor 
Display: Custom (monochrome) digital LCD with backlight 
Operating temperature / humidity: 5 to 40.0 °C / 85% or less relative humidity (no condensation)
Lifetime of the batteries: approx. 400 hours of continuous operation without backlight 
Material: ABS epoxy housing / LaF₃ crystal sensor 
Dimensions: 164 x 29 x 20 mm (without protrusions)
Weight: approx. 55g (including sensor and battery)

 

Included accessories

- 1 & 10 ppm Flouride Standards (14 ml each)
- TISAB (14 ml)
- 5-ml cup
- Sampling sheet B (5 pcs.)
- Syringe
- CR2032 batteries (2 pcs.)
- Instructions for use & short manual 
- Storage case 
Skip product gallery

Replacement sensor, calibration standards and accessories

Horiba LAQUAtwin S060-F Fluoride Replacement Sensor for F-11 tester
Product number: 895695
Measurement parameters: Fluoride | Temperature
The HORIBA LAQUAtwin Pocket Testers provide a comprehensive solution for immediate and precise measurement of water quality parameters directly in the field. To ensure that these measurements remain reliable and accurate, it is essential to regularly check the sensors and replace them with spare sensors if necessary. The replacement sensors, developed specifically for the HORIBA LAQUAtwin series, cover a variety of types for different measurements: pH, conductivity, salinity, redox (ORP), as well as ion-selective sensors for sodium, potassium, nitrate, calcium, and fluoride. Each of these sensors is designed to maximize user-friendliness and precision, qualities for which HORIBA is globally recognized in water quality testing. HORIBA replacement sensors ensure that users’ devices consistently deliver optimal performance and accurate measurements. Advantages of HORIBA Replacement Sensors: Easy Replacement: Sensors can be replaced quickly, allowing measurements to continue without delay. High Precision: Replacement sensors ensure results are accurate and reliable. Comprehensive Measurement Range: Various sensor types are available to measure a wide range of water quality parameters. Durability: Sensors are designed for long service life even under challenging conditions. Sensor Replacement Instructions: To ensure the longevity and accuracy of your HORIBA LAQUAtwin Pocket Tester, follow these steps when replacing a sensor: Removing the Sensor: Turn off the tester. Slightly move the sensor away from the device and lift the sensor tip. Detach the sensor completely from the tester so there is no connection between the two parts. Installing the Sensor: Ensure the tester is turned off. Check that the waterproof gasket is clean and intact. Attach the sensor to the tester by inserting hook “A” on the back of the device into hole “a” on the sensor tip. Ensure that the waterproof gasket is not twisted. Important: After replacing the sensor, follow the instructions in the user manual of the respective tester to make the device ready for accurate measurement. (These manuals are available with the products. Calibration and, if necessary, conditioning are usually required.) How can I check if my sensor shows signs of wear? Check the sensor condition as follows: Perform a 2-point calibration. If an error occurs during calibration, this indicates that the sensor has deteriorated. In this case, it is recommended to replace the sensor. Regular checks and timely replacement of sensors are essential to ensure the high standards and reliability of water quality measurements performed with HORIBA LAQUAtwin Pocket Testers. Manufacturer Part Nr. 3200934450

€205.00*
Horiba 1 ppm Fluoride Ion Standard Solution (514-F-1)
Product number: 895697
Measurement parameters: Fluoride
Optimise your fluoride measurements with this high-quality standard solution – ideal for precise calibration of measuring instruments such as the HORIBA LAQUAtwin F-11. Key features: Concentrated standard solution: 1 ppm fluoride ions – ideal for calibration in the low measurement range.Practical pack: 6 vials of 14 ml each – perfect for frequent and economical use.Compatible with LAQUAtwin F-11: Often used together with 10 ppm and TISAB solutions for two-point calibration. Advantages & application: Maximum accuracy: Calibrate your fluoride measuring devices precisely with the 1 ppm solution – ideal as the first calibration point for a more reliable measurement result.Compact & efficient: Thanks to the 14 ml vials, you can calibrate precisely, avoid waste and save costs.Standard solutions from a single source: Easily supplement with 10 ppm standard and TISAB solutions for a comprehensive calibration series.Easy to use: Just a few drops are enough for calibration – particularly user-friendly for mobile measuring devices or small sample quantities. Areas of application: Environmental analysis & water qualityDrinking water monitoringFood & beverage industrySemiconductor and pharmaceutical industryLaboratories and research   Manufacturer item number: 3200991628

€58.00*
Horiba 10 ppm Fluoride Ion Standard Solution (514-F-10)
Product number: 895698
Measurement parameters: Fluoride
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200991630

€58.00*
Horiba Fluoride Ionic Strength Adjuster (514-F-TISAB)
Product number: 895699
Measurement parameters: Fluoride
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200991632

€58.00*